Question

Write the mass balance equation for a plug-flow system stream with a second order decaying substance,...

Write the mass balance equation for a plug-flow system stream with a second order decaying substance, C.

Find the steady state concentration of C 5km downstream.

The rate constant is 0.3 L mg-1 day-1,

the mean velocity of the river is 0.5 m/s,

and the concentration of C at x=0 is 100mg/l.

Sketch a plot of 1/C as a function of x.

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
Consider a 20 * 105 m3 lake fed by a polluted stream having a flow rate...
Consider a 20 * 105 m3 lake fed by a polluted stream having a flow rate of 4.2 m3/s and pollutant concentration equal to 25 mg/L. There is also a sewage outfall that discharges 0.5 m3/s of wastewater having a pollutant concentration of 275 mg/L. The stream and sewage wastes have a second order decay rate of 0.32/day. Assuming the pollutant is completely mixed in the lake and assuming no evaporation or other water losses or gains, find the steady-state...
A waste stream has a dissolved oxygen concentration of 1.5 mg/L, a flow of 0.5 m3...
A waste stream has a dissolved oxygen concentration of 1.5 mg/L, a flow of 0.5 m3 /s, a temperature of 26°C, and an ultimate BOD (or BODu) of 48 mg/L. The waste stream is discharged into a river that is running at 2.2 m3 /s at a saturated DO, a temperature of 12°C, and an ultimate BOD of 1.6 mg/L. A) Calculate the mixing (a) temperature and (b) ultimate BOD for the river water immediately after discharge of the waste...
Consider a 50 x 10^6 m^3 lake fed by a polluted stream with a flow rate...
Consider a 50 x 10^6 m^3 lake fed by a polluted stream with a flow rate of 75 m^3/s and a pollutant concentration of 25.5 mg/L. There is also a sewage outfall that discharges 3.0 m^3/s of wastewater with a pollutant concentration of 125 mg/L. Stream and sewage waste have a reaction rate coefficient of 5% per day. Find the steady-state (i.e., effluent) pollutant concentration and flow rate.
You are tasked with conducting BOD studies for a waste treatment facility and its discharge to...
You are tasked with conducting BOD studies for a waste treatment facility and its discharge to a nearby river. You are told that the facility removes 93% of the BOD in total with a discharge rate of 1.0 m3 /s. you sample the receiving water and find that it has a 0.5 mg/L deficit from saturation concentration (saturation is at 9.7 mg/L) and a BOD5 content of 10 mg/L. The river flows at a speed of 0.25 m/s and has...
You are tasked with conducting BOD studies for a waste treatment facility and its discharge to...
You are tasked with conducting BOD studies for a waste treatment facility and its discharge to a nearby river. You are told that the facility removes 93% of the BOD in total with a discharge rate of 1.0 m3 /s. you sample the receiving water and find that it has a 0.5 mg/L deficit from saturation concentration (saturation is at 9.7 mg/L) and a BOD5 content of 10 mg/L. The river flows at a speed of 0.25 m/s and has...
Problem #3: Biochemical Oxygen Demand (BOD) and Stream Quality A wastewater treatment plant designed for a...
Problem #3: Biochemical Oxygen Demand (BOD) and Stream Quality A wastewater treatment plant designed for a community of 45,000 people has a flow of 100 gal/person/day and a BOD5 loading of 0.2 lb/person/day. The upstream characteristics of the receiving waters are: stream flow rate = 20 cfs and BOD5 = 2 mg/L The water quality standards require the in-stream BOD5 to be less than 7 mg/L in this stretch of the river. The minimum BOD removal efficiency that the treatment...
Part I. Indicate whether true or false (T or F). ____ Storm water detention ponds typically...
Part I. Indicate whether true or false (T or F). ____ Storm water detention ponds typically are designed to regulate the outflow peak rate at or below a single target value, such as the pre-development (pre-land use change) peak runoff rate for a specified return period event. Detention storage alters the peak but not the volume of the outflow hydrograph. _____ Typical rating curves for weirs are concave upward. Typical rating curves for orifices are concave downward. ____ A sediment...
1) Describe an example of each of the following that may be found of your kitchen:...
1) Describe an example of each of the following that may be found of your kitchen: Explain how your choice falls into this category, and if there is a chemical name or symbol for it, provide that as well. Provide a photo of your example with your ID card in it. a) a compound b) a heterogeneous mixture c) an element (symbol) Moving to the Caves… Lechuguilla Caves specifically. Check out this picture of crystals of gypsum left behind in...
ADVERTISEMENT
Need Online Homework Help?

Get Answers For Free
Most questions answered within 1 hours.

Ask a Question
ADVERTISEMENT