-BRC is a prefabricated welded steel wire mesh or reinforcement wire mesh. The first company which manufactured such Reinforcement wire mesh was British Reinforcement Company Ltd. So initials of the name of the company are used to such products.

-BRC mesh is made up of series of parallel longitudinal wires with accurate spacing welded to cross wires at the specific spacing. Companies produce the mesh with precise dimension control. It reduces the rebar tying process so this way product results in considerable savings time, money and labour.

-It is used in RC slabs, Walkways, Driveways, RC Pavements. It absorbs tensile, shear & compressive stresses.

-BRC is made up of low carbon steel. It comes with wire diameter ranging from A6 to A10.

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
Design a simply supported one-way reinforced concrete floor slab to span 12 ft and carry a...
Design a simply supported one-way reinforced concrete floor slab to span 12 ft and carry a service live load of 180 psf and a service dead load of 20 psf. Use fc’=3000 psi and fy=60,000 psi. Make the slab thickness to 1⁄2 inch increments. (Hint: Design the slab according to the ACI Code minimum thickness)
Reinforced Concrete By using method 3 of ACI code, design a corner slab panel ( 4m...
Reinforced Concrete By using method 3 of ACI code, design a corner slab panel ( 4m x 5.7m ) of a frame building . Use f'c=21MPa, fy=276 MPa, γc=24 kN/m3 and WL=7 kN/m2 . Draw the final design. pls quickly
CONCRETE What kind of concrete is used for the slab, walls, and columns? What is the...
CONCRETE What kind of concrete is used for the slab, walls, and columns? What is the design strength (in psi)? What is the slump? How does the contractor make sure that there will be no voids at the bottom of the walls? Where does the concrete come from? How is the concrete delivery sequenced and coordinated?
The concrete slab of size 40 foot by 36 foot by 5-inch-thick is reinforced with #4...
The concrete slab of size 40 foot by 36 foot by 5-inch-thick is reinforced with #4 rebar at 16 inches on center both ways. The rebar is lapped 18 inches. Determine the number of 20-foot-long bars of #4 rebar needed to reinforce the slab.
When using a cantilevered reinforced concrete slab the equation to solve the coefficient of resistance is...
When using a cantilevered reinforced concrete slab the equation to solve the coefficient of resistance is phi 0.9 or 0.75 and why?
What is development length? Why is the development length important in reinforced concrete design? How is...
What is development length? Why is the development length important in reinforced concrete design? How is the development length typically expressed? What is the top bar effect and why does it increase the development length for concrete? Why does the epoxy coating impact the development length of concrete How does lightweight concrete impact the development length? Do you think it is safe to reduce the development length if you provide more steel than you are required in your design? If...
You are working on a mix design and have been asked by the engineer to recommend...
You are working on a mix design and have been asked by the engineer to recommend the maximum size aggregate that can be used in the mix. The concrete is for a continuously reinforced concrete slab. The slab is 10 inches thick and will be reinforced with No. 6 bars (3/4-inch diameter) at 6 inch on-center (so a 5 1⁄4 inch space between the bars). The bars will be placed just above mid-depth of the slab so they have 4...
2. Design a reinforced concrete beam of 20 feet span carrying a uniformly distributed load of...
2. Design a reinforced concrete beam of 20 feet span carrying a uniformly distributed load of 1200 lbs/ft. Use Fc = 3,000 psi and steel stress of 20,000 psi and assume appropriate modulus of elasticity and other required material properties.
Design the formwork for a suspended concrete roof slab 8 in. thick. Sheathing will be 3/4-in...
Design the formwork for a suspended concrete roof slab 8 in. thick. Sheathing will be 3/4-in Ply form (structural 1), while 2 x 4 in. Southern Pine will be used for the joists. Stringer will be 4 x 4 in. Southern Pine. Assume that all members are continuous over three or more spans. Commercial 4000-lb shores will be used. It is estimated that the weight of the formwork will be 10 lb. /sq. ft. Maximum deflection of form members will...
Design a wall footing to support a 300 mm reinforced concrete wall with dead load of...
Design a wall footing to support a 300 mm reinforced concrete wall with dead load of 292KN/m and live load of 200 KN/m. The bottom of the footing is 1.20 m below the final grade, the soil weighs 15,700 N/m3. The allowable soil pressure is 190 Kpa. fy = 276.5 Mpa, fc’ = 27.6 Mpa.
ADVERTISEMENT
Need Online Homework Help?

Get Answers For Free
Most questions answered within 1 hours.

Ask a Question
ADVERTISEMENT