Question

rapid sand filter will constructed for average flow rate of 0.06 m3 / h. Design find...

rapid sand filter will constructed for average flow rate of 0.06 m3 / h. Design find the dimensions and draw filter.

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
A rapid filter unit is to produce a maximum flow of 23,000 m3 /day. The nominal...
A rapid filter unit is to produce a maximum flow of 23,000 m3 /day. The nominal filtration rate is 120 m/day and is not to exceed 180 m/day with one filter being backwashed nor 240 m/day with one filter being backwashed and one filter out of service. Determine the number of filter units required and the individual filter area. How much water is required to wash one filter if the backwash rate is 1 m/min and the duration is 10...
A utility wants to design a granular media filter using sand and anthracite. Given that the...
A utility wants to design a granular media filter using sand and anthracite. Given that the sand has an average diameter of 0.9 mm and the anthracite has an effective diameter of 1.5 mm, how deep should the filter bed be? Note – there is a range of bed depths for media based on particle size – please state your assumptions.
Design a slow sand filter system for a community which has a projected population of 3000...
Design a slow sand filter system for a community which has a projected population of 3000 and an average per capita use of 300 litres/day. Determine the total filter area needed to produce water to meet demand at a maximum weekly rate and a filtration rate of 6.0 m/day. Use Goodrich formula to determine the maximum weekly water consumption rate. What is the filter area of each filter if three filters are to be used with one out of service?
A rectangular shaped sedimentation tank is to be built for a design flow of 600 m3/h....
A rectangular shaped sedimentation tank is to be built for a design flow of 600 m3/h. If the detention time, overflow rate and weir loading rate are 3 hours, 50 m3/m2.d, 100 m3/m.d, calculate the length, width and depth of the tank and the weir length. (assume length to width ratio of 3:1) (8 points)
Design a cubic rapid mixer for a water treatment plant with a peak flow rate of...
Design a cubic rapid mixer for a water treatment plant with a peak flow rate of 20,000 m3/d.  Assume the velocity gradient G in the mixer is to be at least 1,000 s-1and the detention time is at least 10 s. Determine the size of the mixing tank, the power input, and the rotational speed of the mixer if the radial flow impeller power number is 6.0
A water treatment plant has five identical rapid sand filters. Each is square in plan and...
A water treatment plant has five identical rapid sand filters. Each is square in plan and has a capacity of 1 MGD. The application rate is to be 4 gal/min-ft2 and the total wetted depth is 10 ft. Each filter will be backwashed every day for 5 min. The rate of rise of the backwash water is 2 ft/min. A) What should be the cross-section dimensions of each filter? B) What percentage of the plant's filtered water will be used...
A box of volume 36 m3 with square bottom and no top is constructed out of...
A box of volume 36 m3 with square bottom and no top is constructed out of two different materials. The cost of the bottom is $40/m2 and the cost of the sides is $30/m2 . Find the dimensions of the box that minimize total cost. (Let s denote the length of the side of the square bottom of the box and h denote the height of the box.) (s, h) =
.Calculate the effluent BOD of 2 Stage trickling filter with the following data: Flow rate =...
.Calculate the effluent BOD of 2 Stage trickling filter with the following data: Flow rate = 3.15 m3/min, BOD5 = 290 mg/lt V1 = V2 = 830 m3, Filter depth = 3 m Recirculation of filter1 = 125% of Q Recirculation of filter2 = 100% of Q
Dechlorination contact tank (Wastewater Treatment) An activated sludge plant has a design flow (average daily flow)...
Dechlorination contact tank (Wastewater Treatment) An activated sludge plant has a design flow (average daily flow) of 11 MGD. Determine dimensions of dechlorination tank. The design parameters: use 1 tank. detention time = 30 sec, depth = 10 ft, rectangular tank: L = 4 W. use maximum hourly flow (3 * Average design flow)
10.4 - The first order analog low pass filter H(s) = 1500/(s + 1500) must be...
10.4 - The first order analog low pass filter H(s) = 1500/(s + 1500) must be transformed into a digital filter operating with an 8 kHz sampling rate. a. Prewarp the cut-off frequency for the filter and modify the analog transfer function accordingly. b. Find the transfer function for the digital filter. c. Find the difference equation for the filter. d. Find the frequency response and draw the filter shape. e. Find the digital filter shape directly from the magnitude...