Question

A column is to be used to support a critical vertical load of 6000 kN. The...

A column is to be used to support a critical vertical load of 6000 kN. The column is 6 m long and having pin at one end and fixed at another end and restrained in weak axis. Modulus of Elasticity (E) of structural steel is 200,000 MPa. Suggest Most suitable UC from manufacture’s catalogue .

Unsupported length of column = 6m

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
(30 pts) A short reinforced concrete column is subjected to a 1000 kN axial compressive load....
(30 pts) A short reinforced concrete column is subjected to a 1000 kN axial compressive load. The moduli of elasticity of plain concrete and steel are 25 GPa and 207 GPa, respectively, and the cross-sectional area of steel is 2% of that of the reinforced concrete. Considering the column as a structural member made of a composite material and subjected to load parallel to the steel rebars, calculate the following: a. the modulus of elasticity of the reinforced concrete b....
Determine if the following column is long or short, and then determine the critical load on...
Determine if the following column is long or short, and then determine the critical load on a steel column having a rectangular cross section, 12mm by 18mm and a length of 250 mm. It is fixed on both ends and made from a steel that has the following properties: E= 209 Gpa and sy = 290 Mpa. Slenderness ratio = ___________ Cc = _______ Long or short column = ___________ Critical load = ____________________ Newtons
During construction, field tests were conducted to assess the suitability of the column to withstand a...
During construction, field tests were conducted to assess the suitability of the column to withstand a safe buckling load of 2.5 kN assuming a factor of safety 4 using two different hollow columns made up of steel and concrete. Both columns have same cross section but varying length and different support conditions. Steel column of length 3 m having external diameter 40 mm was tested with one end fixed and the other end hinged, when subjected to a compressive stress...
1: During construction, field tests were conducted to assess the suitability of the column to withstand...
1: During construction, field tests were conducted to assess the suitability of the column to withstand a safe buckling load of 2.5 kN assuming a factor of safety 4 using two different hollow columns made up of steel and concrete. Both columns have same cross section but varying length and different support conditions. Steel column of length 3 m having external diameter 40 mm was tested with one end fixed and the other end hinged, when subjected to a compressive...
Which will support more load when used as a building column: 1) A 6" x 6"...
Which will support more load when used as a building column: 1) A 6" x 6" (actual size) wood ( Douglas Fir) post 16 feet long, pinned at both ends or 2) A structural steel W10 x 39 I-beam 20 feet long, pinned at the ends