Question

why increase volume of sedimentation can increase effectiveness of a sedimentation why increase volume of sedimentation...

why increase volume of sedimentation can increase effectiveness of a sedimentation

why increase volume of sedimentation basin can increase effectiveness of a sedimentation

Homework Answers

Answer #1

Sedimentation is a physical process used for water treatment by gravity to remove suspended solids from the water. In this sedimentation tank, water is entered at inlet which flow towards outlet with some velocity and during this time the particles which are heavier in weight settles at bottom of tank but rest of the particles remains in suspension which are lighter . So, when the volume of sedimentation basin is increases the flow through period of water containing suspended solids is increases which means water take more time to flow toward outlet . Due to which lighter particles also starts settle at bottom of tank and hence efficiency of tank or basin is increased. So, due to which effectiveness of basin is increased.

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
). A sedimentation basin is constructed to treat 6.43 million gallon every day. If the basin...
). A sedimentation basin is constructed to treat 6.43 million gallon every day. If the basin having volume of 1.45 Million gallon and surface area of 10544 sq-ft, calculate the detention time and overflow rate the sedimentation basin
A rectangular sedimentation basin receives water at 10 degrees Celsius with a flow rate of 0.5...
A rectangular sedimentation basin receives water at 10 degrees Celsius with a flow rate of 0.5 m3/s. The sedimentation basin is 20m wide, 60m long, and 6m deep. The effective settling zone in the sedimentation basin is 45 m long. Determine the number of double sided weir troughs placed parallel to the length (L) of the basin.
A countercurrent lamella settler module is to be installed in a conventional sedimentation tank that is...
A countercurrent lamella settler module is to be installed in a conventional sedimentation tank that is 19m long, 3m wide, 3.4m deep. The flow through the basin is 500m^3/h. The settler module's lamella area 1.3m long, spaced at 5cm intervals, and inclined at 45 degrees. The module will occupy 50% of the tank surface area sp that the resulting velocity through the channels is 15m/h. Find the critical settling velocity of the lamella settler, and compare it to the overflow...
In the sedimentation basin design, explain when the hydraulic design should address the peak flow in...
In the sedimentation basin design, explain when the hydraulic design should address the peak flow in the wastewater treatment
11.24 Calculate the dimensions of a launder around the periphery of a 10.0 m-radius sedimentation basin....
11.24 Calculate the dimensions of a launder around the periphery of a 10.0 m-radius sedimentation basin. A critical flow condition exists at the outlet end of the launder. The design flow for this basin is 5000 m3/d. Assume that the channel width is 300 mm and that the flow will divide equally around the two halves of the basin. The launder is made with smooth concrete.
1) How decreasing the heart rate can increase stroke volume? 2) why is possible for heart...
1) How decreasing the heart rate can increase stroke volume? 2) why is possible for heart to increase stoke volume when the End Diastolic Volume? 3) And whose Law is this?
A rectangular horizontal-flow sedimentation basin in a conventional water treatment plant has been designed to treat...
A rectangular horizontal-flow sedimentation basin in a conventional water treatment plant has been designed to treat a flow of 50,000 m3 /day. It has a length = 80 m, width = 20 m, and depth = 3.6 m. For this problem, assume temperature = 20 °C (density of water = 103 kg/m3 and viscosity = 10-3 kg/m·s) and laminar flow. a. What is the hydraulic detention time? Does this meet the typical criteria for this type of sedimentation basin? b....
1) A drinking water treatment plant uses a cubic rapid mix, rectangular flocculation basin, and rectangular...
1) A drinking water treatment plant uses a cubic rapid mix, rectangular flocculation basin, and rectangular sedimentation basin to treat 10.0 mgd of water. Size the volume for each basin using the characteristic detention time and flow through velocity requirements. What is the rapid mix volume for Dt = 30 sec? What is the floc. basin volume for Dt = 30 min? What is the floc. basin cross-sectional area for a velocity = 10.0 ft/min? What is the sed. basin...
5. Volume can increase and open interest can decrease on the same trading day. True or...
5. Volume can increase and open interest can decrease on the same trading day. True or False
Can Apple and Samsung Collude to increase their profits? Why or why not?