Question

Determine if the following column is long or short, and then determine the critical load on...

Determine if the following column is long or short, and then determine the critical load on a steel column having a rectangular cross section, 12mm by 18mm and a length of 250 mm. It is fixed on both ends and made from a steel that has the following properties: E= 209 Gpa and sy = 290 Mpa.

Slenderness ratio = ___________ Cc = _______ Long or short column = ___________ Critical load = ____________________ Newtons

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
A 6-m long column is made of a steel girder W200x52 (see the section properties in...
A 6-m long column is made of a steel girder W200x52 (see the section properties in the last page). It is loaded concentrically through the centroid of the section. Given that the steel has the elastic modulus Est = 210 GPa and the yield stress Y = 340 MPa. Determine the critical load (Euler Buckling Load, Pcr) where the support at the column ends are fixed-free support
For a 8m long column whose cross sectional dimensions are 0.1m x 0.4m, determine the allowable...
For a 8m long column whose cross sectional dimensions are 0.1m x 0.4m, determine the allowable load using a safety factor of 2.5. The column is welded at both ends. Its yield stress is 250 MPa and its modulus of elasticity is 210 GPa. using Euler Formula or J. B. Johnson Formula.
3. Calculate the load carrying capacity and percentage of reinforcement for a short rectangular column of...
3. Calculate the load carrying capacity and percentage of reinforcement for a short rectangular column of cross section dimension 280 mm x 500 mm is reinforced with 4 bars of 25 mm diameter, 2 bars of 20 mm diameter and 2 bars of 12 mm diameter. Use M30 grade concrete and Fe 500 grade steel. Also design a 4 legged ties necessary for this section.
(30 pts) A short reinforced concrete column is subjected to a 1000 kN axial compressive load....
(30 pts) A short reinforced concrete column is subjected to a 1000 kN axial compressive load. The moduli of elasticity of plain concrete and steel are 25 GPa and 207 GPa, respectively, and the cross-sectional area of steel is 2% of that of the reinforced concrete. Considering the column as a structural member made of a composite material and subjected to load parallel to the steel rebars, calculate the following: a. the modulus of elasticity of the reinforced concrete b....
A column is to be used to support a critical vertical load of 6000 kN. The...
A column is to be used to support a critical vertical load of 6000 kN. The column is 6 m long and having pin at one end and fixed at another end and restrained in weak axis. Modulus of Elasticity (E) of structural steel is 200,000 MPa. Suggest Most suitable UC from manufacture’s catalogue . Unsupported length of column = 6m
A hollow circular steel column 2m long and outer diameter 200 mm carries an axial load...
A hollow circular steel column 2m long and outer diameter 200 mm carries an axial load of 325 kN. If the compressive stress is 150 MPa, lateral strain for external diameter is is 0.000325 and Poisson’s ratio is 0.3, find the minimum wall thickness required for the column. Also calculate the shear modulus for the material of the column. Take E = 210 GPa.   
Determine the nominal compressive strength Pn of a short column which subjected to biaxial bending ex-...
Determine the nominal compressive strength Pn of a short column which subjected to biaxial bending ex- 250 mm , ey- 150 mm h - 650 mm , b - 450 mm , reinforcement 8 28.ties 10 mm , cover - 40mm fc - 28 Mpa , fy 420 MPa Determine the nominal compressive strength Pn of a short column which subjected to biaxial bending ex- 250 mm , ey- 150 mm h - 650 mm , b - 450 mm...
CE Board May 2012 A 450 mm square interior column carries a dead load of 825...
CE Board May 2012 A 450 mm square interior column carries a dead load of 825 KN and a live load of 668 KN. A rectangular footing is required to carry the column loads such that the length of the long side must be equal to twice the width of the short side. Assume base of footing is 1.5 m below the ground surface. Allowable bearing pressure of soil is 15.74 KN/m3 and that of concrete is 23.5 KN/m3. Use...
Determine the nominal compressive strength Pn of a short column which subjected to biaxial bending ex-...
Determine the nominal compressive strength Pn of a short column which subjected to biaxial bending ex- 250 mm , ey- 150 mm h - 650 mm , b - 450 mm , reinforcement 8 28.ties 10 mm , cover - 40mm fc - 28 Mpa , fy 420 MPa
A simply supported beam is 3 m long. It carries a uniformly distributed load of 6...
A simply supported beam is 3 m long. It carries a uniformly distributed load of 6 kN/m throughout its span and a concentrated load of 15 kN at a point 2 m from the left support. Assuming that the beam has a rectangular shape whose width and depth are 150 mm and 250 mm, respectively. Determine the maximum flexural stress in MPa developed in the beam.