Question

In a water system, you are installing a valve that will operate at two positions: fully...

In a water system, you are installing a valve that will operate at two positions: fully open or closed. Which valve will cause the most minor loss? GIVEN: equivalent length in pipe diameters Le/D (Globe valve: 340, Angle valve: 150, Gate valve: 8, Check valve: 100).

The options are: a)Globe vale b)Angle valve c)Gate valve c)check valves

Please provide a clear explanation.

Homework Answers

Answer #1

The Correct Option : a)Globe value

Explanation: Generally loss is given by

hL=K(v2/2g)

where K=resistance coefficient =(Le/D)*ft

(Le/D) ratio values are already given ,So

for Globe valve = 340 ft

for Angle valve = 150 ft

for gate valve = 8 ft

for check valve = 100 ft

  1. when we multiply with friction factor , the Globe valve get higher value obviously total minior loss will be higher .
  2. however it is one of the poorest performing valves in terms of energy loss.
  3. Due to the higher (Le/D) value it also having most minor loss Because it have complex path to travel.
  4. so option C is correct.