Question

Air at 98 kPa and 30.6°C flows upward through a 6-cm-diameter inclined duct at a rate...

Air at 98 kPa and 30.6°C flows upward through a 6-cm-diameter inclined duct at a rate of 87 L/s. The duct diameter is then reduced to 4 cm through a reducer. The pressure change across the reducer is measured by a water manometer. The elevation difference between the two points on the pipe where the two arms of the manometer are attached is 0.20 m. Determine the differential height between the fluid levels of the two arms of the manometer. (Take g=9.81 m/s², R= 0.287 kPa. m³/kg.K, I m³ = 1000L).

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
Air at 373°C and 121 kPa flows through a horizontal 7 cm diameter pipe at a...
Air at 373°C and 121 kPa flows through a horizontal 7 cm diameter pipe at a speed of 50 m/s. If the air changes temperature to 375°C at a constant pressure, what is the value of the change in the flow of kinetic energy? Write your result in J/s.
A liquid of density 1270 kg/m3 flows steadily through a pipe of varying diameter and height....
A liquid of density 1270 kg/m3 flows steadily through a pipe of varying diameter and height. At Location 1 along the pipe, the flow speed is 9.81 m/s and the pipe diameter d1 is 11.3 cm. At Location 2, the pipe diameter d2 is 17.1 cm. At Location 1, the pipe is Δy=9.59 m higher than it is at Location 2. Ignoring viscosity, calculate the difference ΔP in units of Pa between the fluid pressure at Location 2 and the...
A fluid with SG:0,888 and viscosity:0,8 Pa s flows in horizontal pipe of diameter:5 cm and...
A fluid with SG:0,888 and viscosity:0,8 Pa s flows in horizontal pipe of diameter:5 cm and length:40 m.The measured velocity profile is of parabolic shape.The amount of pressure difference between inlet and exist of the pipe is 648,76 kPa.Determine Reynolds number of flow if the pipe is inclined at an angle 30 degree with horizontal and flow is upward with the same pressure difference is applied                        
1.) A liquid of density 1390 km/m^3 flows steadily through a pipe of varying diameter and...
1.) A liquid of density 1390 km/m^3 flows steadily through a pipe of varying diameter and height. At Location 1 along the pipe, the flow speed is 9.31 m/s and the pipe d1 diameter is 10.3cm . At Location 2, the pipe diameter d2 is 17.5 cm . At Location 1, the pipe is triangle y= 9.31m higher than it is at Location 2. Ignoring viscosity, calculate the difference between the fluid pressure at Location 2 and the fluid pressure...
A liquid of density 1.33 × 103 kg/m3 flows steadily through a pipe of varying diameter...
A liquid of density 1.33 × 103 kg/m3 flows steadily through a pipe of varying diameter and height. At location 1 along the pipe the flow speed is 9.15 m/s and the pipe diameter is 11.5 cm. At location 2 the pipe diameter is 17.3 cm. At location 1 the pipe is 9.89 m higher than it is at location 2. Ignoring viscosity, calculate the difference between the fluid pressure at location 2 and the fluid pressure at location 1.
A liquid of density 1.19 × 103 kg/m3 flows steadily through a pipe of varying diameter...
A liquid of density 1.19 × 103 kg/m3 flows steadily through a pipe of varying diameter and height. At location 1 along the pipe the flow speed is 9.79 m/s and the pipe diameter is 10.7 cm. At location 2 the pipe diameter is 14.1 cm. At location 1 the pipe is 8.75 m higher than it is at location 2. Ignoring viscosity, calculate the difference between the fluid pressure at location 2 and the fluid pressure at location 1.
A liquid of density 1.37 × 103 kg/m3 flows steadily through a pipe of varying diameter...
A liquid of density 1.37 × 103 kg/m3 flows steadily through a pipe of varying diameter and height. At location 1 along the pipe the flow speed is 9.47 m/s and the pipe diameter is 11.1 cm. At location 2 the pipe diameter is 17.1 cm. At location 1 the pipe is 9.37 m higher than it is at location 2. Ignoring viscosity, calculate the difference between the fluid pressure at location 2 and the fluid pressure at location 1.
A liquid of density 1.13 × 103 kg/m3 flows steadily through a pipe of varying diameter...
A liquid of density 1.13 × 103 kg/m3 flows steadily through a pipe of varying diameter and height. At location 1 along the pipe the flow speed is 9.77 m/s and the pipe diameter is 11.3 cm. At location 2 the pipe diameter is 14.5 cm. At location 1 the pipe is 8.43 m higher than it is at location 2. Ignoring viscosity, calculate the difference between the fluid pressure at location 2 and the fluid pressure at location 1.
A liquid of density 1150 kg/m3 flows steadily through a pipe of varying diameter and height....
A liquid of density 1150 kg/m3 flows steadily through a pipe of varying diameter and height. At Location 1 along the pipe, the flow speed is 9.99 m/s and the pipe diameter ?1 is 12.3 cm . At Location 2, the pipe diameter ?2 is 17.9 cm . At Location 1, the pipe is Δ?=8.79 m higher than it is at Location 2. Ignoring viscosity, calculate the difference Δ? between the fluid pressure at Location 2 and the fluid pressure...
A liquid of density 1370 kg/m3 flows steadily through a pipe of varying diameter and height....
A liquid of density 1370 kg/m3 flows steadily through a pipe of varying diameter and height. At Location 1 along the pipe, the flow speed is 9.51 m/s and the pipe diameter d1 is 11.9 cm. At Location 2, the pipe diameter d2 is 14.1 cm. At Location 1, the pipe is Δy=8.55 m higher than it is at Location 2. Ignoring viscosity, calculate the difference ΔP between the fluid pressure at Location 2 and the fluid pressure at Location...
ADVERTISEMENT
Need Online Homework Help?

Get Answers For Free
Most questions answered within 1 hours.

Ask a Question
ADVERTISEMENT