Question

A venturimeter is used to measure water flow rate of 7.5m^3/min. If pressure difference between the...

A venturimeter is used to measure water flow rate of 7.5m^3/min. If pressure difference between the wide and throat sections of the venturi is 12.50 kPa, and the pipe diameter at the wide section is 20 cm, calculate the throat diameter. (Use density=1000 kg/m^3 and coefficient of discharge Cd=0.96).

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
1.2 A horizontal Venturi meter is used to measure the flow of water in a 400mm...
1.2 A horizontal Venturi meter is used to measure the flow of water in a 400mm diameter pipe. The throat diameter of the Venturi meter is 100mm and the the discharge coefficient is 0.85. if the pressure difference between the two measurement points is 10cm of mercury, then calculate the average velocity in the pipe. take the relative density of mercury as 13.6. b) What diameter pipe would be required to double the capacity for the 400mm concrete conduit pipe...
A Venturi tube exhibits a pressure difference of 25 kPa (between the sections) with a fluid...
A Venturi tube exhibits a pressure difference of 25 kPa (between the sections) with a fluid of density 1025 kg/m3 flowing from section 2 where the radius is 4.25 cm to section 1 which has a radius of 2.00 cm. Calculate: (a) the velocity of the fluid in section 1 (b) the velocity of the fluid in section 2 (c) the volume rate of flow in each section
I'm needing assistance calculating the flow rate of a venturi Pipe diameter upstream of venturi, Da-...
I'm needing assistance calculating the flow rate of a venturi Pipe diameter upstream of venturi, Da- 10in Diameter of venturi neck, Db: 7 in Pressure difference measured by venturi, Dp: 10 Pa Fluid density, r: 1.29lb/in^3 Discharge Coefficient, C: 0.98. [Please show me how these calculations were reached]
A pump delivers water (r= 1000 kg/m3, µ= 0.860x10-3 kg/m·s) from one reservoir to another reservoir...
A pump delivers water (r= 1000 kg/m3, µ= 0.860x10-3 kg/m·s) from one reservoir to another reservoir through 120 m of 0.05 m diameter pipe. Volumetric flow rate in the pipe line is measured with venturi meter. Throat diameter of venturi meter is 38 mm and pressure drop in the venturi meter is 156.9 kPa.The surface of the pipe is rough e/D=0.0001. Calculate the power of the pump required for the water–transfer. See the figure below for several pipe– fittings installed...
An orifice plate flow sensor is used to measure the flow of water in a 2-in....
An orifice plate flow sensor is used to measure the flow of water in a 2-in. ID pipe. The orifice plate has a 1.5-in. diameter hole. The pressure difference across the plate is 0.3 psi. Find the approximate water flow in the pipe.
Suppose air, with a density of 1.29 kg/m3 is flowing into a Venturi meter. The narrow...
Suppose air, with a density of 1.29 kg/m3 is flowing into a Venturi meter. The narrow section of the pipe at point A has a diameter that is 0.402 times the diameter of the larger section of the pipe at point B. The U-shaped tube is filled with water and the difference in height between the two sections of pipe is h = 1.96 cm. How fast is the air moving at point B?
4. A Diff. Pressure flow meter is calibrated to measure the flow of gas within 10...
4. A Diff. Pressure flow meter is calibrated to measure the flow of gas within 10 – 40 kg/min. the flow meter is designed to give 5 – 15 KPa differential pressure. And the meter 4-20 mA signal is designed to be linear with flow. (6) a. Find the pressure difference and the current at 20kg/min flow? b. Find the flow at 7 KPa pressure difference?
Water flows through a horizontal pipe at a rate of 2.3 m3/s. A pressure gauge placed...
Water flows through a horizontal pipe at a rate of 2.3 m3/s. A pressure gauge placed on a 40 cm diameter section of the pipe reads 210.3 kPa. What is the gauge pressure in a section of pipe where the diameter is constricted to 35 cm and what has caused this change in pressure?
Water flows through a horiztonal pipe at a rate of 94 ft3/min. A pressure gauge placed...
Water flows through a horiztonal pipe at a rate of 94 ft3/min. A pressure gauge placed on a 3.5 inch diameter section of the pipe reads 15 psi. What is the gauge pressure in a section of pipe where the diameter is 5.4 inches?
A tank is filled with 8m water (density water = 1000 kg/m^3) and 2 m oil...
A tank is filled with 8m water (density water = 1000 kg/m^3) and 2 m oil (density oil = 900 kg/ m^3).Flow is discharged at the bottom from a circular exit section with 5 mm diamter. Ignoring all frictional effects, determine the a) Velocity in exit section if the top tank pressure is atmospheric b) Flow rate in exit section if the top tank pressure is -25 kPa vacuum.