Question

A hollow circular steel column 2m long and outer diameter 200 mm carries an axial load...

A hollow circular steel column 2m long and outer diameter 200 mm carries an axial load of 325 kN. If the compressive stress is 150 MPa, lateral strain for external diameter is is 0.000325 and Poisson’s ratio is 0.3, find the minimum wall thickness required for the column. Also calculate the shear modulus for the material of the column. Take E = 210 GPa.
  

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
(30 pts) A short reinforced concrete column is subjected to a 1000 kN axial compressive load....
(30 pts) A short reinforced concrete column is subjected to a 1000 kN axial compressive load. The moduli of elasticity of plain concrete and steel are 25 GPa and 207 GPa, respectively, and the cross-sectional area of steel is 2% of that of the reinforced concrete. Considering the column as a structural member made of a composite material and subjected to load parallel to the steel rebars, calculate the following: a. the modulus of elasticity of the reinforced concrete b....
A hollow right circular cylinder is made of cast iron and has an outside diameter of...
A hollow right circular cylinder is made of cast iron and has an outside diameter of 75 mm and an inside diameter of 60 mm. If the cylinder is loaded by an axial compressive force of 50 KN, determine the total shortening (in mm) in a 600-mm length. Take the modulus of elasticity to be 100 GPa and neglect any possibility of lateral buckling of the cylinder. show the solution
Due to the operational conditions and temperature gradient, a 70 mm diameter, 1.55 m long steel...
Due to the operational conditions and temperature gradient, a 70 mm diameter, 1.55 m long steel rod within a machine assembly is subjected to a combination of tensile loading of 150 N and thermal loading which imposes a longitudinal force of 230 N. The total loading results in an even distribution of forces on the body of the rod causing it to change its dimensions by increasing 0.5 mm in length at both ends and decreasing by 0.0125 mm at...
A composite member is made of a hollow steel pipe with an inner diameter of 12”...
A composite member is made of a hollow steel pipe with an inner diameter of 12” and wall thickness 1”. The hollow steel pipe is filled with concrete and subjected to a compressive force of 120,000 lbs. The member length is 25’. The modulus of elasticity of concrete and steel are Ec = 3,600,000 psi and Es = 30,000,000 psi, respectively. Calculate the axial and compressive loads resisted by the steel and concrete. Fconcrete = 45000 lbs ; Fsteel =...
The drive shaft AB of an automobile with 1.7 m long is made of a steel...
The drive shaft AB of an automobile with 1.7 m long is made of a steel having an allowable shear stress τall = 60 MPa and modulus of rigidity G = 80 GPa. Limit angle of twist of the shaft is 0.035 rad. If the outer diameter of the shaft is 65 mm and the engine delivers 180 kW to the shaft when it is turning at 1170 rev/min, determine the minimum required thickness of the shaft’s wall.
A 6-m long column is made of a steel girder W200x52 (see the section properties in...
A 6-m long column is made of a steel girder W200x52 (see the section properties in the last page). It is loaded concentrically through the centroid of the section. Given that the steel has the elastic modulus Est = 210 GPa and the yield stress Y = 340 MPa. Determine the critical load (Euler Buckling Load, Pcr) where the support at the column ends are fixed-free support
A bar of hollow circular cross section has an outer diameter of 50 mm, an inner...
A bar of hollow circular cross section has an outer diameter of 50 mm, an inner diameter of 40 mm, and a length of 3 m. The bar is used as a structural member in a pin-jointed framework, and an analysis has shown that it is subjected to a compressive axial force of 500 N. As part of a buckling analysis, assuming the bar is pin-jointed at each end, the effective slenderness ratio is then: which option is correct 133...
During construction, field tests were conducted to assess the suitability of the column to withstand a...
During construction, field tests were conducted to assess the suitability of the column to withstand a safe buckling load of 2.5 kN assuming a factor of safety 4 using two different hollow columns made up of steel and concrete. Both columns have same cross section but varying length and different support conditions. Steel column of length 3 m having external diameter 40 mm was tested with one end fixed and the other end hinged, when subjected to a compressive stress...
1: During construction, field tests were conducted to assess the suitability of the column to withstand...
1: During construction, field tests were conducted to assess the suitability of the column to withstand a safe buckling load of 2.5 kN assuming a factor of safety 4 using two different hollow columns made up of steel and concrete. Both columns have same cross section but varying length and different support conditions. Steel column of length 3 m having external diameter 40 mm was tested with one end fixed and the other end hinged, when subjected to a compressive...
ADVERTISEMENT
Need Online Homework Help?

Get Answers For Free
Most questions answered within 1 hours.

Ask a Question
ADVERTISEMENT