Question

Deign a square tied column to support a service axial dead load P_d of 200 K...

Deign a square tied column to support a service axial dead load P_d of 200 K and a live load P_l of 300 K using concrete f_c^'=4000 psi and bars f_y=60000psi (use steel ratio of about 3% design the ties and check the ACI code requirements) ACI-318

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
Design the largest axially loaded rectangular column with the aspect ratio of b/h = 1.5 to...
Design the largest axially loaded rectangular column with the aspect ratio of b/h = 1.5 to support an axial dead load of 350 k and axial live load of 380 k. f’c = 4000 psi, fy= 60,000 psi.
Design a square axially loaded short square tied column for concentric ultimate axial load Pu =...
Design a square axially loaded short square tied column for concentric ultimate axial load Pu = 2600 kN. f’c = 28 MPa and fy = 350 MPa. assume ρ = 0.02. Draw the section details showing dimensions, cover, rebars, stirrups (ties), ..etc.
A 24 in. x 16 in. column on the second floor of a multi-story building is...
A 24 in. x 16 in. column on the second floor of a multi-story building is to be designed to carry a live load of 500,000 lb, and a dead load that is 75 % of the live load (includes self weight). The nominal moment is calculated to be 5,769 kip.in. Use the interaction diagrams with γ = 0.8 to design the column reinforcement for a concrete strength of 4000 psi and a steel strength of 60000 psi. Include the...
A short reinforced concrete column is subjected to a 700 kips axial compressive load. The modulus...
A short reinforced concrete column is subjected to a 700 kips axial compressive load. The modulus of elasticity of plain concrete and steel are 4,500,000 psi and 29,000,000, respectively, and the cross-sectional area of steel is 3.0% of that of the reinforced concrete. Considering the column as a structural member made of a composite material and subjected to load parallel to the steel bars. Calculate the modulus of elasticity of the reinforced concrete, as well as how much load is...
A short, square tied column has a minimum area of reinforcing steel of 3.24 in2 and...
A short, square tied column has a minimum area of reinforcing steel of 3.24 in2 and a gross area of 18 in2. The compressive strength of the concrete is 4000 lbf/in2 and the yield strength of the steel is 60,000 lbf/in2. What is most nearly the design axial compressive load capacity? A) 130 kips B) 140 kips C) 570 kips D) 400 kips
A 500mm width square tied column with reinforcement on four faceshas a gross steel ratio is...
A 500mm width square tied column with reinforcement on four faceshas a gross steel ratio is 0.02 and the concrete cover from the column surface to the steel centroid is 100 mm. what is the nominal axial capacity of the column if subjected to biaxial bending where ex=ey=250 mm? use fy'=21 Mpa and fy= 415 Mpa, reciprocal load method and interaction diagram below.
CE Board May 2012 A 450 mm square interior column carries a dead load of 825...
CE Board May 2012 A 450 mm square interior column carries a dead load of 825 KN and a live load of 668 KN. A rectangular footing is required to carry the column loads such that the length of the long side must be equal to twice the width of the short side. Assume base of footing is 1.5 m below the ground surface. Allowable bearing pressure of soil is 15.74 KN/m3 and that of concrete is 23.5 KN/m3. Use...
Design a one-way floor slab to carry a uniform live load of 500 psf on a...
Design a one-way floor slab to carry a uniform live load of 500 psf on a simply supported span of 21 ft, given fc’=4000 psi and fy=50000 psi. Use the ACI 318 code. Keep the reinforcement ratio at about 30% of the amount of balanced strain condition so that deflection is unlikely to be excessive.
Design a wall footing to support a 300 mm reinforced concrete wall with dead load of...
Design a wall footing to support a 300 mm reinforced concrete wall with dead load of 292KN/m and live load of 200 KN/m. The bottom of the footing is 1.20 m below the final grade, the soil weighs 15,700 N/m3. The allowable soil pressure is 190 Kpa. fy = 276.5 Mpa, fc’ = 27.6 Mpa.
A reinforced concrete square column (0.26m × 0.26m) is supported by a square isolated footing (spread...
A reinforced concrete square column (0.26m × 0.26m) is supported by a square isolated footing (spread footing). The footing is of plain concrete, and concentrically loaded. An engineer has suggested 1.25m × 1.25m footing. First, check the sufficiency of footing dimension. If it is not sufficient, design the footing in accordance with the requirements of ACI 318M-08 and using the following available data: Net allowable soil pressure: net qa = 170 kPa Column loads (unfactored): D = 160 kN L...