Question

A 50 mm diameter tube has a length of 35 m and inclined upward with 15...

A 50 mm diameter tube has a length of 35 m and inclined upward with 15 degree with the horizontal (Figure). The discharge is 5.5 L/s and the outlet pressure required to be 75 kPa gage pressure. Estimate the inlet gage pressure in kPa of this tube if the coefficient of friction (f) in the losses equation   is 0.03.

Homework Answers

Answer #1

Inlet pressure = 246.155 kPa

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
A horizontal tapering pipebend of 45 degree, has inlet diameter of 600 mm and outlet diameter...
A horizontal tapering pipebend of 45 degree, has inlet diameter of 600 mm and outlet diameter of 300 mm. The pressure at its inlet end is 150 KPa and discharge through the bend is 0.5 m3/s. Determine the magnitude of the force exertedby the water on the bend.
1. The diameter of the discharge pipe of a centrifugal pump is 15 cm and the...
1. The diameter of the discharge pipe of a centrifugal pump is 15 cm and the that of the intake pipe is 20 cm The pressure gage connected to the discharge pipe at the pump outlet reads 207 kPa, and the vacuum gage connected to the intake pipe at the pump inlet reads 25 cm of mercury. If the pump discharge is 84.7 L/s and the power needed to run the pump is 35 HP, what is the pump efficiency?
Air flows in a pipe with a diameter, D=50 mm. The inlet conditions are: M1 =...
Air flows in a pipe with a diameter, D=50 mm. The inlet conditions are: M1 = 3; total pressure, P01 = 1000 kPa absolute; and temperature, T1 = 550 K. The friction coefficient is, f = 0.004. The exit Mach number decreases with the length of the pipe. Write a Matlab code and plot the following while the exit Mach number to be changed from 2.5 to 0.99 with decrements of ?M=0.01: a) L, length of the pipe that is...
A condenser is made up of a horizontal tube bank (0.75 m long, 200 mm diameter)....
A condenser is made up of a horizontal tube bank (0.75 m long, 200 mm diameter). Saturated steam at 143.3 kPa condenses on the outside surface of the tubes. The surface temperature is maintained at 90°C. Evaluate the condensation rate and heat transfer coefficient if the bank consists of 15 tubes.
The tube shown has a length of 2.00 m and a diameter of 1.00 mm. Water...
The tube shown has a length of 2.00 m and a diameter of 1.00 mm. Water at 40° C is flowing through the tube. For water at 40° C: A) What pressure difference is required to give the water a flow speed of 4.0 m/s? (Give your answer in units of Pa.) B) What force applied to the end of the tube will produce this pressure? (Give your answer in units of N.) C) What is the volume flow rate...
A 10-mm diameter tube has a maintained surface temperature of 200°C. Engine oil enters the tube...
A 10-mm diameter tube has a maintained surface temperature of 200°C. Engine oil enters the tube at 70°C at a flow rate of 0.5 kg/s and exits at 105°C. Find the length, in m, of the tube and well as the corresponding heat transfer rate, in W. Assume fully developed flow and use the Dittus–Boelter equation to calculate the average Nusselt number. q = .    L =
1- Water flows in a 10 m long and 4 cm diameter pipe contains 4 elbows...
1- Water flows in a 10 m long and 4 cm diameter pipe contains 4 elbows ( KL= 0.2 ) at velocity 8 m/s. Calculate the total head losses when the friction factor f=0.03 35.56 m 22.07 m 27.07 m 15.46 m 2- water flows in a 10 m long and 5 cm diameter horizontal pipe at rate 15 l/s Calculate the pressure drop Take the density of water 1000 kg/m3 and the dynamic viscosity 0.001 kg/m.s 74.13 kPa 96.41...
A shell and-tube heat exchanger is required for the following service: Hot stream Cold Stream Aromatic...
A shell and-tube heat exchanger is required for the following service: Hot stream Cold Stream Aromatic Stream Cooling Water inlet Temperature (oC) 85 20 outlet Temperature (oC) 40 35 Mass Flowrate x heat Capacity (kW/oC) 85.2 Hot Stream cold stream (Cooling water) Heat Capacity (J/kg K) 2840 4193 Density (kg/m3) 750 999 Viscosity (cP) 0.34 1.016 Thermal conductivity (W/m.K) 0.19 0.594 Fouling Factor (m2.oC/W 0.00018 0.000176 ? The cooling water is allocated to the tube-side of the exchanger. ? It...
ADVERTISEMENT
Need Online Homework Help?

Get Answers For Free
Most questions answered within 1 hours.

Ask a Question
ADVERTISEMENT