Question

what are 2 ways to achieve a better resolution of two proteins on a size exclusion...

what are 2 ways to achieve a better resolution of two proteins on a size exclusion chromatography column?

What are 2 reasons for protein recovery loss from a size exclusion chromatogrpahy column?

Homework Answers

Answer #1

Size exclusion chromatography media with high uniformity and narrow particle size distribution facilitate the elution of molecules in sharp peaks. Size exclusion chromatography media with smaller particle sizes facilitate diffusion of sample molecules in and out of the particles by reducing the time to achieve equilibrium between mobile and stationary phases and so improve resolution by reducing peak width.

Protein is unstable or inactive in the buffer.

. Protein has been degraded by proteases.

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
For size-exclusion chromatography, how would one increase ​BOTH​ column resolution and accuracy of a molecular weight...
For size-exclusion chromatography, how would one increase ​BOTH​ column resolution and accuracy of a molecular weight calculation of a substance?
1. Which of the following answers is (are) true about size exclusion chromatography? a. large proteins...
1. Which of the following answers is (are) true about size exclusion chromatography? a. large proteins elute first b. small proteins interact more with the column c. proteins larger than the cutoff size do not elute d. will be used to purify GFP 2. Which of the following is (are) not true about ion exchange chromotagraphy? a. positively charged proteins elute first b. negatively charged proteins elute first c. uncharged proteins elute first d. hydrophobic proteins elute first 3. The...
1. please answer TRUE or FALSE 1) In size exclusion chromatography, the smallest proteins are eluted...
1. please answer TRUE or FALSE 1) In size exclusion chromatography, the smallest proteins are eluted last. 2) Single-stranded RNA molecules can have extensive regions of intramolecular base pairing leading to defined secondary and tertiary structure. 2. Applications of mass spectrometry include: detection of post-translational modifications on proteins. determination of the mass of a protein. determining the primary structure of proteins. A and B. A, B, and C. 3. Please answer the blank The nucleotide sequence of a polynucleotide chain...
In a mixture of five proteins listed below, which should elute first in a size-exclusion chromatography...
In a mixture of five proteins listed below, which should elute first in a size-exclusion chromatography under non-denaturing conditions?   Note that the size-exclusion resin can only resolve proteins from 25 kDa to 200,000 kDa​ A. RNA polymerase, MW 450,000 Da B. Immunoglobin G, MW 145,000 Da C. Serum albumin, MW 67,000 Da D. Ribonuclease D, MW 17,000 Da E. Cytochrome c, MW 13,000 Da
Some characteristics of three proteins are listed in the table below: Protein Molecular Weight (Da) Isoelectric...
Some characteristics of three proteins are listed in the table below: Protein Molecular Weight (Da) Isoelectric point (pI) Does the Protein Contain a heme moiety? 1 65,000 5.5 No 2 54,000 10.0 No 3 14,500 4.5 Yes a.(2 points) What type of chromatography separates proteins based on size? b. (2 points) What type of chromatography separates proteins based on their charge? c.(10 points) Could gel filtration chromatography be used to separate a mixture containing Protein 2 and 3? Clearly explain...
Bacterial media often contains specific proteins digested into smaller parts. There are two common ways proteins...
Bacterial media often contains specific proteins digested into smaller parts. There are two common ways proteins are digested. What are the two ways? Due to the method of digestion of the protein, the digestion products resulting may differ. How?
Given the following table of protein information, what is the order (first to last) in which...
Given the following table of protein information, what is the order (first to last) in which you would assume proteins would come off a gel filtration (size exclusion chromatography) column? Molecular Wt. (da) pI(ioselectric point Protein 1 9,000 7.1 Protein 2 49,000 6.3 Protein 3 25,000 6.0 a. Protein 1, Protein 2, Protein 3 b. Protein 3, Protein 2, Protein 1 c. Protein 2, Protein 1, Protein 3 d. Protein 2, Protein 3, Protein 1 e. Protein 1, Protein 3,...
you have following proteins protein PI MM Specific tag 1 6.4 28700 his6 tag 2 4.5...
you have following proteins protein PI MM Specific tag 1 6.4 28700 his6 tag 2 4.5 33100 no tag 3 6.5 210111 HIS6 TAG Which of the following methods would be the best method for separation? 2d gel electrophoresis, ion exchange size exclusion isoeletric focusing native page SDS page affinity chromatography 2D page
List two different ways you could change the buffer to elute the bound protein(s) and achieve...
List two different ways you could change the buffer to elute the bound protein(s) and achieve proper separation of the proteins. Select all that apply. Please explain why. add a buffer with pH=8.0 add a buffer with pH=5.0 decreasing the ionic strength of the buffer increasing the ionic strength of the buffer
1. Why does the structure difference of ribose and deoxyribose matter in protein synthesis? 2. What...
1. Why does the structure difference of ribose and deoxyribose matter in protein synthesis? 2. What are two reasons why proteins are made from polyamides rather than polyesters? 3. Why monosubstituted amides instead of disubstituted amides in proteins?
ADVERTISEMENT
Need Online Homework Help?

Get Answers For Free
Most questions answered within 1 hours.

Ask a Question
ADVERTISEMENT