Question

A sample has a measured absorbance of 1.51 in a spectrophotomer with Pstray = 0.55% of...

A sample has a measured absorbance of 1.51 in a spectrophotomer with Pstray = 0.55% of Po. What is the true absorbance of the sample?

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
A 0.0000831 M sample of Compound X in a solvent has an absorbance of 0.349 at...
A 0.0000831 M sample of Compound X in a solvent has an absorbance of 0.349 at 528 nm in a 1.000-cm cuvet. The solvent alone has an absorbance of 0.056. What is the molar absorptivity of Compound X? A different sample of Compound X in the same solvent has an absorbance of 0.501 at 528 nm when measured with the same cuvet. What is the concentration of this second sample?
A 0.0000552 M sample of Compound X in a solvent has an absorbance of 0.266 at...
A 0.0000552 M sample of Compound X in a solvent has an absorbance of 0.266 at 528 nm in a 1.000-cm cuvet. The solvent alone has an absorbance of 0.052. What is the molar absorptivity of Compound X? A different sample of Compound X in the same solvent has an absorbance of 0.528 at 528 nm when measured with the same cuvet. What is the concentration of this second sample?
The absorbance of a cationic iron(II) sample solution was measured in a spectrophotometer, but the instrument...
The absorbance of a cationic iron(II) sample solution was measured in a spectrophotometer, but the instrument returned an error because the absorbance was too high. The sample was then diluted by using a pipette to take 100.0 μL of the sample and injecting it into a cuvette already containing 2.00 mL of water (total volume is 2.00 mL + 100.0 μL). The absorbance value of the diluted solution corresponded to a concentration of 8.21×10−6 M . What was the concentration...
are measuring the concentration of Fe2 in a sample by measuring the absorbance of its complex...
are measuring the concentration of Fe2 in a sample by measuring the absorbance of its complex with ferroxine. Your sample, measured in a 1.00-cm pathlength cuvette, has an absorbance of 0.208 while the reagent blank in the same cuvette has an absorbance of 0.046. What would be the absorbance reading of these two solutions if measured in a cuvette with 8.00 cm pathlength?
If a solution has an absorbance of 0.100 in a 1.00 cm pathlength cuvette, what would...
If a solution has an absorbance of 0.100 in a 1.00 cm pathlength cuvette, what would the absorbance be in a cuvette of 0.55 cm pathlength cell?
Calculate the molar concentration of a solution that has a measured absorbance of 0.635 using a...
Calculate the molar concentration of a solution that has a measured absorbance of 0.635 using a 1-cm pathlength cuvette and an extinction coefficient of 46,000.0 M-1cm-1.
An opaque sample has infinite absorbance. However, the maximum obtainable absorbance reading from a given a...
An opaque sample has infinite absorbance. However, the maximum obtainable absorbance reading from a given a UV-Vis spectrophotometer is limited by “stray light” inside the instrument—light that somehow reaches the detector without actually traveling through the sample. What is the maximum reading if this stray light is 0.1% of the light transmitted through a blank sample? What stray light percentage would be required for a maximum absorbance reading of 5?
Penny sample absorbance value has to be the highest and lowest absorbance values for standard solutions....
Penny sample absorbance value has to be the highest and lowest absorbance values for standard solutions. Explain why this is important.
Suppose an unknown sample has an absorbance which is significantly larger than the absorbance of the...
Suppose an unknown sample has an absorbance which is significantly larger than the absorbance of the most concentrated standard and so is outside the range of the calibration curve. What should the analyst do to accurately determine the concentration for the unknown using Beers law? Extending the calibration curve or using the equation for the line are not correct answers to this question.
The absorbance of a 0.18 M colored solution was measured with red light and found to...
The absorbance of a 0.18 M colored solution was measured with red light and found to be 0.281. If the same curvette was cleaned, used, and dried what would you predict the absorbance to be for each of the following solution concentration? a. 0.27 M solution b. 0.36 M solution c. 0.90 M solution
ADVERTISEMENT
Need Online Homework Help?

Get Answers For Free
Most questions answered within 1 hours.

Ask a Question
ADVERTISEMENT