Question

Experimental Organic Chemistry 1 HPLC Questions - How do you predict the elution order of compounds?...

Experimental Organic Chemistry 1

HPLC Questions

- How do you predict the elution order of compounds?

-What's the difference between the mobile phase and the stationary phase?

Homework Answers

Answer #1

In normal phase column where silica is the stationary phase non-polar compounds elute first. Silica is polar. It holds the polar compounds tightly to itself. The non-polar compounds are less tightly held. Therefore, non-polar compounds elute first.

In reverse phase column where silica surface is modified with long chain hydrocarbons, the polar compounds elute first. The long chain hydrocarbons make silica surface hydrophobic. They hold non-polar molecules more tightly than the polar compounds. Therefore, the polar compounds elute first.

The mobile phase is the solvent or mixture of solvents which is passed through the stationary phase which does not move. Stationary phase is the column of HPLC which is either packed with silica (normal phase) or modified silica with n-octylsilyl (C-8) or n-octadecylsilyl (C-18) moieties on silica (reverse phase).

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
Order the following compounds in order of elution in gas chromatography. Explain your reasoning. conditions: Mobile...
Order the following compounds in order of elution in gas chromatography. Explain your reasoning. conditions: Mobile Phase – Air (Flow Rate = 25 mL/min), Stationary Phase –poly(dimethylsiloxane),Oven Temperature – 110 oC. 1-pentanol, 2-hexanol, 2-pentanone, pentane b) How would a gradient elution (55 oC – 120 oC) impact the chromatogram?
The stationary phase of the GC columns in the organic chemistry labs is silicone oil, and...
The stationary phase of the GC columns in the organic chemistry labs is silicone oil, and so the boiling points of the sample compounds determine the order of elution. The highest boiling species is the last to elute from the column. In the analysis of your distillation fractions by GC, the peak that elutes firstfrom the column will correspond to which component of the mixture?
These questions are from The Wittig Reaction: Chemiluminescence. 1. Predict the order of elution of a...
These questions are from The Wittig Reaction: Chemiluminescence. 1. Predict the order of elution of a mixture of 9-anthraldehyde and (E)-9-(2-phenylethenyl)-anthracene on a TLC plate using a 5:1 hexanes/ethyl acetate eluent mixture. 2. How do you predict that cooling and warming your chemiluminescence reaction mixture after initial mixing will affect the reaction? 3. A glow stick contains: a dye molecule, an oxalate ester, and hydrogen peroxide. Two of these components have to be separated until it is time to use...
1. Predict the order of elution of fluorene and fluorenone from an alumina chromatography column. Explain...
1. Predict the order of elution of fluorene and fluorenone from an alumina chromatography column. Explain your answer in terms of each compound’s structure and polarity and its interaction with the alumina stationary phase 2. Upon development, the fluorene standard usually shows a spot due to fluorene and a second spot which has a much lower Rf value. What is the second component and why does it form?
Please answer the following questions about the Thin-Layer Chromatography The principle of TLC (mobile/stationary phase) How/why...
Please answer the following questions about the Thin-Layer Chromatography The principle of TLC (mobile/stationary phase) How/why do compounds separate on a TLC plate?
1. If you load the mixture of compounds using more than a "minimal amount of CH2Cl2",...
1. If you load the mixture of compounds using more than a "minimal amount of CH2Cl2", what will happen to your separation? A. The seperation will be poor since CH2Cl2 is a less polar solvent than petroleum ether. B. The seperation will be improved since CH2Cl2 is a more polar solvent than petroleum ether C. The seperation will be improved since CH2Cl2 is a less polar solvent than petroleum ehter D. The seperation will be poor since CH2Cl2 is a...
Organic Chemistry Lab: Distillation. a.) In vacuum distillation, how you do ensure that the liquid does...
Organic Chemistry Lab: Distillation. a.) In vacuum distillation, how you do ensure that the liquid does not boil too suddenly upon reduction of pressure? b.) When carrying out a fractional distillation, i.) What is the ideal boiling point difference for the two components of the mixture you are distilling? ii.) what needs to be adjusted if the boiling point difference is smaller than above?
INORGANIC CHEMISTRY QUESTION IR Questions 1. Why do the CO stretches occur in a much higher...
INORGANIC CHEMISTRY QUESTION IR Questions 1. Why do the CO stretches occur in a much higher frequency region than C=O stretches in organic carbonyl compounds? 2.Why do Metal-Hydride stretches occur at much lower frequency than C-H stretches?
This is an organic chemistry lab question.The experiment is on relative reactivities of some aromatic compounds....
This is an organic chemistry lab question.The experiment is on relative reactivities of some aromatic compounds. I'll give an overview of how what I did in the experiment and what i need help with. This might look like a lot but i really do need some help. I used 0.070ml of Anisole + 0.5ml of Glacial acetic acid. I added 1.00ml of bromine/hydrobromic acid. the mixture was heated for about 15 minuted (a moistened sodium disulfide wool apparatus was attached...
Hello, I missed this lab for organic chemistry and need to do a flowchart (extraction flowchart)....
Hello, I missed this lab for organic chemistry and need to do a flowchart (extraction flowchart). This is the procedure and I am not sure whats going on with this part... "Remove the organic phase and extract the aqueous layer with 15 mL of ethyl acetate." How would I draw a flowchart for this? Here is the rest of the procedure before that step if you need it... 1. In a 50 mL round bottom flask equipped with a magnetic...