Question

Volumetric Pipet Procedure: Order the steps for the procedure for using the volumetric pipet to deliver...

Volumetric Pipet Procedure:

Order the steps for the procedure for using the volumetric pipet to deliver a fixed volume of water. 1-First Step, 8-Last Step.

( )Before starting make sure that the pipet is clean and is not chipped.

( )When done, rinse pipet with tap water and then distilled water before storing.

( )Now fill the pipet with liquid to above the calibration mark or line with suction from bulb -- without getting liquid in the bulb.

( )Drain freely into the receiver container, wait 5 seconds after flow stops and touch off last drop to transfer all of the calibrated volume.

( )Before starting the transfer rinse the pipet by partially filling it with liquid to be delivered-- do not get liquid in bulb.

( )Wipe the excess liquid off the lower stem and tip of pipet. (This step before the final adjustment of the meniscus level to the mark).   

( )Remove bulb and immediately cover the top of the pipet stem with your index finger.

( )Adjust level so the bottom of the meniscus is on the calibration mark by slow release of pressure.

Homework Answers

Answer #1

( 1) Before starting make sure that the pipet is clean and is not chipped.

(8 )When done, rinse pipet with tap water and then distilled water before storing.

( 3)Now fill the pipet with liquid to above the calibration mark or line with suction from bulb -- without getting liquid in the bulb.

(7 )Drain freely into the receiver container, wait 5 seconds after flow stops and touch off last drop to transfer all of the calibrated volume.

( 2)Before starting the transfer rinse the pipet by partially filling it with liquid to be delivered-- do not get liquid in bulb.

(5 )Wipe the excess liquid off the lower stem and tip of pipet. (This step before the final adjustment of the meniscus level to the mark).   

( 4)Remove bulb and immediately cover the top of the pipet stem with your index finger.

( 6)Adjust level so the bottom of the meniscus is on the calibration mark by slow release of pressure.

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
Procedure Experiment 1: Standardize an NaOH Solution Using Benzoic Acid as Primary Standard Part 1: Prepare...
Procedure Experiment 1: Standardize an NaOH Solution Using Benzoic Acid as Primary Standard Part 1: Prepare the NaOH Solution Take a 250 mL volumetric flask from the Containers shelf and a balance from the Instruments shelf and place them on the workbench. Zero the mass of the volumetric flask on the balance. Take sodium hydroxide from the Materials shelf and add 1 g to the flask. Record the mass from the balance display. Place the volumetric flask on the workbench....
Why does the infinity reaction not require an infinite amount of time? PROCEDURE: Prepare 60 mL...
Why does the infinity reaction not require an infinite amount of time? PROCEDURE: Prepare 60 mL of a 1:1 (by volume) solution of distilled water and 2-propanol in a beaker. Be as precise as possible. After mixing well, wait 10-15 minutes to allow the contents to come to room temperature as some heat will evolve during the mixing of the two liquids. Obtain ~20 mL of 0.05M NaOH and put it in a small plastic storage bottle. Set up a...
Assuming you weighed out a 2.3684 g sample of your unknown, and dissolved and diluted it...
Assuming you weighed out a 2.3684 g sample of your unknown, and dissolved and diluted it as in the procedure below, and it took 35.63 mL of a 0.1025 M HCl titrant to reach the endpoint, what are the weight percents of Na2CO3 and NaHCO3 in your unknown sample? Hints: -Set g Na2CO3 = X -Eqn A: bicarbonate + carbonate = diluted weighted mass (remember, the mass is not 2.3684, you diluted it before you titrated it.Calculate the diluted g...
Procedure Preparation of Reagents 1. Starch indicator will be provided 2. Solid potassium iodide will be...
Procedure Preparation of Reagents 1. Starch indicator will be provided 2. Solid potassium iodide will be available 3. 0.3 M H2SO4 will be available 4. ~0.04 M Sodium thiosulfate solution will be provided. You should be able to complete the experiment with 250 mL of this solution. 5. Preparation of 0.01M KIO3 Solution: a. Accurately weigh approximately 0.535 g of solid reagent and record the mass to 4 decimal places. b. Deliver the KIO3 to a 250 mL volumetric flask...
Procedure Reaction 1: Dissolving the Copper 1. Obtain a clean, dry, glass centrifuge tube. 2. Place...
Procedure Reaction 1: Dissolving the Copper 1. Obtain a clean, dry, glass centrifuge tube. 2. Place a piece of copper wire in a weighing paper, determine the mass of the wire and place it in the centrifuge tube. The copper wire should weigh less than 0.0200 grams. 3. In a fume hood, add seven drops of concentrated nitric acid to the reaction tube so that the copper metal dissolves completely. Describe your observations in the lab report. (Caution, Concentrated nitric...
Experiment 1: Titrations With Hot Taco Sauce and Ketchup Materials: (2) 250 mL Beakers 100 mL...
Experiment 1: Titrations With Hot Taco Sauce and Ketchup Materials: (2) 250 mL Beakers 100 mL Beaker (waste beaker) 30 mL Syringe Syringe stopcock 100 mL Graduated cylinder Funnel Stir rod Ring stand Ring Clamp pH meter Scale 20 mL 0.1M NaOH 2 Ketchup packets 2 Hot sauce packets *90 mL Distilled water *Scissors *Computer Access *Access to a Graphing Software *Procedure for creating this solution provided in the "Before You Begin..." section (located at the beginning of the manual)....