Enzyme X has a molecular weight of 48,000. It converts substrate Z into product Y. Z absorbs at 340nm, and Y absorbs at 480nm
A.) At what wavelength do you measure the change in absorbance to assay for enzyme X? Does the absorbance increase or decrease over time?
B.) If Vmax= 60 micromol/min and you use 400 microliters of a 0.1mg/mL solution of enzyme, what is the turnover number?
A) We can measure the disappearance of Z at 340 nm (absorbance
will decrease), or we can measure the increase in Y at 480 nm
(absorbance will increase). This will not measure the enzyme, but
will measure the enzyme activity.
B) Turnover number = Vmax/Et
Vmax is the maximum velocity and Et is
total amount of enzyme
Vmax = 60 µ mol/min
Et = 0.4mL x 0.1mg/mL = 0.04 mg
enzyme (400 µL = 0.4 mL)
Turnover number = (60 µmol/min) /(0.04 mg)
Turnover number =1500 µmol/min/mg