Question

Co(II) was used as an internal standard to analyze a sample of Ti(IV) with atomic absorption...

Co(II) was used as an internal standard to analyze a sample of Ti(IV) with atomic absorption spectroscopy (AAS). A standard mixture containing 1.98 μg Co/mL and 1.81 μg Ti/mL measured by AAS produced a signal-to-signal ratio of 2.73 Ti: 1.00 Co. A mixture was prepared by combining 4.00 mL of a Ti(IV) solution of unknown concentration with 3.50 mL of a 13.9 μg/mL solution of Co(II). The absorbance of the mixture at the Ti(IV) wavelength was 0.116 and the absorbance at the Co(II) wavelength was 0.185. Determine the concentration, in moles per liter, of Ti(IV) in the original unknown solution.

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
Co(II) was used as an internal standard to analyze a sample of Ti(IV) with atomic absorption...
Co(II) was used as an internal standard to analyze a sample of Ti(IV) with atomic absorption spectroscopy (AAS). A standard mixture containing 1.84 μg Co/mL and 2.44 μg Ti/mL measured by AAS produced a signal-to-signal ratio of 2.85 Ti: 1.00 Co. A mixture was prepared by combining 4.00 mL of a Ti(IV) solution of unknown concentration with 3.00 mL of a 12.8 μg/mL solution of Co(II). The absorbance of the mixture at the Ti(IV) wavelength was 0.125 and the absorbance...
Cobalt was used as an internal standard to analyze a sample of titanium with atomic absorption...
Cobalt was used as an internal standard to analyze a sample of titanium with atomic absorption spectroscopy. A mixture was prepared by combining a 6.00 mL Ti solution of unknown concentration with 2.50 mL of a 13.9 μg/mL solution of Co. The atomic absorbances were measured as 0.155 and 0.208 for Ti and Co, respectively. As a reference, a standard mixture containing 1.78 μg Co/mL and 1.09 μg Ti/mL was prepared and measured to have a signal-to-signal ratio of 2.06...
Cobalt was used as an internal standard to analyze a sample of titanium with atomic absorption...
Cobalt was used as an internal standard to analyze a sample of titanium with atomic absorption spectroscopy. A mixture was prepared by combining a 4.00 mL Ti solution of unknown concentration with 3.50 mL of a 12.3 μg/mL solution of Co. The atomic absorbances were measured as 0.103 and 0.212 for Ti and Co, respectively. As a reference, a standard mixture containing 2.20 μg Co/mL and 2.48 μg Ti/mL was prepared and measured to have a signal-to-signal ratio of 1.79...
atomic absorption spectroscopy was used to analyze a sample of ground water for arsenic concentration following...
atomic absorption spectroscopy was used to analyze a sample of ground water for arsenic concentration following the method of standard additions. First,the sample was measured, and found to have an absorbance of 0.435. Next, 10 ul of a standard solution of arsenic(1000ug/ml) was added to 10ml of the sample. This solution 9which contained sample and the standard addition) was measured, and found to have an absorbance of 0.661. What was the concentration of arsenic in the sample?
Atomic absorption spectrometry was used with the method of standard additions to determine the concentration of...
Atomic absorption spectrometry was used with the method of standard additions to determine the concentration of cadmium in a sample of an industrial waste stream. For the addition, 10.0 μL of a 1000.0 μg/mL Cd standard was added to 10.0 mL of solution. The following data were obtained: Absorbance of reagent blank = 0.042 Absorbance of sample = 0.390 Absorbance of sample plus addition = 0.733. What was the concentration of the cadmium in the waste stream sample? Later, the...
3) Cerium(IV) sulfate  is used to titrate a solution of iron(II) ions, with which it reacts according...
3) Cerium(IV) sulfate  is used to titrate a solution of iron(II) ions, with which it reacts according to Ce4+(aq) + Fe2+(aq) = Ce3+(aq) + Fe3+(aq) A cerium(IV) sulfate solution is prepared by dissolving 38.14 g of Ce(SO4)2 in water and diluting to a total volume of 1.000 L. A total of 17.82 mL of this solution is required to reach the endpoint in a titration of a 250.0-mL sample containing Fe2+(aq). Determine the concentration of Fe2+ in the original solution. answer:...