Question

A BOD test was conducted on the unchlorinated effluent of a municipal wastewater treatment plant at...

A BOD test was conducted on the unchlorinated effluent of a municipal wastewater treatment plant at 20°C. The wastewater portion added to a 300-mL BOD bottle was 30 mL, and the dissolved oxygen (DO) values listed below were measured using a dissolved-oxygen probe. No seed was added to the bottles. What is the BOD value for each “valid” sample? Valid samples are ones that do not violate the following two rules:

1. DOf is less than 1.0 mg/L (unclear if still an aerobic bottle) and

2. DOi-DOf < 2.0 mg/L (imprecise measurement).

Time (days), DO (mg/L): 0.01,8.7 1.0,7.8 4.0,5.7 6.0,4.9 10.0,3.9 14.0,0.5

1 - sampled just after preparation of sample bottles.

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
A BOD test was run in a 300 mL bottle on a 30 mL dilution of...
A BOD test was run in a 300 mL bottle on a 30 mL dilution of water with a 5 mL seed. The BOD5 of the seed was 150 mg/L. The initial dissolved oxygen level in the water was 7.9 mg/L, The day 5 level of dissolved oxygen in the bottle was 4.7 mg/L. What is the BOD5 of the water sample?
A wastewater treatment plant disposes of its effluent in a surface stream. Characteristics of the stream...
A wastewater treatment plant disposes of its effluent in a surface stream. Characteristics of the stream and effluent are given in the table below. What will be the dissolved oxygen concentration in the stream after 2.0 days? (10 Points) What will be the lowest dissolved oxygen concentration as a result of the waste discharge? (10 Points) Parameter Wastewater Stream Flow, m3/s 0.2 5.0 Dissolved Oxygen, mg/L 1.0 8.0 Temperature, o C 15.0 20.2 BOD5 at 20oC, mg/L 100 2.0 k1...
You are tasked with conducting BOD studies for a waste treatment facility and its discharge to...
You are tasked with conducting BOD studies for a waste treatment facility and its discharge to a nearby river. You are told that the facility removes 93% of the BOD in total with a discharge rate of 1.0 m3 /s. you sample the receiving water and find that it has a 0.5 mg/L deficit from saturation concentration (saturation is at 9.7 mg/L) and a BOD5 content of 10 mg/L. The river flows at a speed of 0.25 m/s and has...
You are tasked with conducting BOD studies for a waste treatment facility and its discharge to...
You are tasked with conducting BOD studies for a waste treatment facility and its discharge to a nearby river. You are told that the facility removes 93% of the BOD in total with a discharge rate of 1.0 m3 /s. you sample the receiving water and find that it has a 0.5 mg/L deficit from saturation concentration (saturation is at 9.7 mg/L) and a BOD5 content of 10 mg/L. The river flows at a speed of 0.25 m/s and has...
A wastewater treatment plant with a zero dissolved oxygen, discharges 10,000 m3/d to a small stream....
A wastewater treatment plant with a zero dissolved oxygen, discharges 10,000 m3/d to a small stream. The stream average flow is 0.4 m3/s with a dissolved oxygen level of 8 mg/l and a BOD5 of 2 mg/l. The minimum oxygen demand that must be maintained in the stream is 4 mg/l. Determine the maximum BOD5 that can be discharged if the initial ultimate BOD after the mixing is 8.1 mg/l. The BOD reaction rate is 0.23 d-1.
Problem #3: Biochemical Oxygen Demand (BOD) and Stream Quality A wastewater treatment plant designed for a...
Problem #3: Biochemical Oxygen Demand (BOD) and Stream Quality A wastewater treatment plant designed for a community of 45,000 people has a flow of 100 gal/person/day and a BOD5 loading of 0.2 lb/person/day. The upstream characteristics of the receiving waters are: stream flow rate = 20 cfs and BOD5 = 2 mg/L The water quality standards require the in-stream BOD5 to be less than 7 mg/L in this stretch of the river. The minimum BOD removal efficiency that the treatment...
A BOD test is run using 80 mL of treated wastewater mixed with 160 mL of...
A BOD test is run using 80 mL of treated wastewater mixed with 160 mL of pure water. The initial DO of the mix is 8.0 mg/L. After 5 days, the DO is 4.0 mg/L. After a long period of time, the DO is 2.0 mg/L, and it no longer seems to be dropping. Assume nitrification has been inhibited so the only BOD being measured is carbonaceous. a. What is the five-day BOD of waste wastewater? b. Assuming no nitrification...
At a wastewater-treatment plant FeCl3(s) is added to remove excess phosphate from the effluent. Assume that...
At a wastewater-treatment plant FeCl3(s) is added to remove excess phosphate from the effluent. Assume that the reactions that occur are: FeCl3(s) <> Fe3+ + 3Cl- FePO4 <> Fe3+ + PO43- The equilibrium constant for the second reaction is 10-26.4. What concentration of Fe3+ would be needed to maintain the phosphate concentration below the limit of 1 mg/L of P? (Hint: Assume all the P is in the PO43- form so we’re asking for 1 mg/L PO4 3- as P.)...
You have been retained to design a wastewater treatment plant using a conventional activated sludge process...
You have been retained to design a wastewater treatment plant using a conventional activated sludge process for a town of 40,000 people. The industrial flow contribution to the sewer system is 300,000 gallons per day. Effluent discharge standards require effluent BOD5 and total suspended solids concentration of <10 mg/l. Assume the following design criteria are applicable: Domestic sewage flow = 100 gal/cap/day (including I/I) BOD loading = 0.18 lbs/cap/day TSS loading = 0.20 lbs/cap/day BOD removal in primary = 33%...
ADVERTISEMENT
Need Online Homework Help?

Get Answers For Free
Most questions answered within 1 hours.

Ask a Question
ADVERTISEMENT