Question

A wastewater treatment plant disposes of its effluent in a surface stream. Characteristics of the stream...

A wastewater treatment plant disposes of its effluent in a surface stream. Characteristics of the stream and effluent are given in the table below.

What will be the dissolved oxygen concentration in the stream after 2.0 days? (10 Points)

What will be the lowest dissolved oxygen concentration as a result of the waste discharge? (10 Points)

Parameter

Wastewater

Stream

Flow, m3/s

0.2

5.0

Dissolved Oxygen, mg/L

1.0

8.0

Temperature, o C

15.0

20.2

BOD5 at 20oC, mg/L

100

2.0

k1 at 20oC, d-1

0.2

-

K2 at 20oC, d-1

-

0.3

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
Effluent from a wastewater-treatment plant is discharged to a surface stream. The characteristics of the effluent...
Effluent from a wastewater-treatment plant is discharged to a surface stream. The characteristics of the effluent and the stream are given in the table below. Determine the stream characteristics after mixing has occurred. Parameter Effluent Stream Flow, 8500 m3/day 1.5 m3/sec BOD5, mg/L 25.0 2.0 Ammonia, mg/L 10.0 0.0 Nitrate, mg/L 7.0 3.0 Chloride, mg/l 15 5.0
A wastewater treatment plant with a zero dissolved oxygen, discharges 10,000 m3/d to a small stream....
A wastewater treatment plant with a zero dissolved oxygen, discharges 10,000 m3/d to a small stream. The stream average flow is 0.4 m3/s with a dissolved oxygen level of 8 mg/l and a BOD5 of 2 mg/l. The minimum oxygen demand that must be maintained in the stream is 4 mg/l. Determine the maximum BOD5 that can be discharged if the initial ultimate BOD after the mixing is 8.1 mg/l. The BOD reaction rate is 0.23 d-1.
The City of Columbus recently issued an NPDES permit to a beer brewery discharging wastewater at...
The City of Columbus recently issued an NPDES permit to a beer brewery discharging wastewater at a flowrate of 0.15 m3/sec into Buckeye Creek (flowrate = 0.25 m3/sec), such that BOD5 of immediately after discharge must not exceed 2.5 mg/L. Upstream of the discharge, BOD5 in Buckeye Creek was measured at 1.5 mg/L. BOD decay rate constants were measured separately for the upstream creek (k = 2 d-1), the wastewater effluent (k = 0.2 d-1), and the downstream creek after...
A BOD test was conducted on the unchlorinated effluent of a municipal wastewater treatment plant at...
A BOD test was conducted on the unchlorinated effluent of a municipal wastewater treatment plant at 20°C. The wastewater portion added to a 300-mL BOD bottle was 30 mL, and the dissolved oxygen (DO) values listed below were measured using a dissolved-oxygen probe. No seed was added to the bottles. What is the BOD value for each “valid” sample? Valid samples are ones that do not violate the following two rules: 1. DOf is less than 1.0 mg/L (unclear if...
The volumetric flow to the ACME wastewater treatment plant is 25 MGD. The influent soluble BOD5...
The volumetric flow to the ACME wastewater treatment plant is 25 MGD. The influent soluble BOD5 is 200 mg/L and the effluent soluble BOD5 is 8 mg/L. The plant is designed to operate with a mean cell (biomass) residence time of 10 days. The yield coefficient is 0.6 mg biomass/mg substrate, and the biomass decay rate is 0.09/day. The reactor is to operate at a biomass concentration of 2500 mg/L. The thickened underflow biomass concentration from the secondary clarifier is...
Problem #3: Biochemical Oxygen Demand (BOD) and Stream Quality A wastewater treatment plant designed for a...
Problem #3: Biochemical Oxygen Demand (BOD) and Stream Quality A wastewater treatment plant designed for a community of 45,000 people has a flow of 100 gal/person/day and a BOD5 loading of 0.2 lb/person/day. The upstream characteristics of the receiving waters are: stream flow rate = 20 cfs and BOD5 = 2 mg/L The water quality standards require the in-stream BOD5 to be less than 7 mg/L in this stretch of the river. The minimum BOD removal efficiency that the treatment...
You are tasked with conducting BOD studies for a waste treatment facility and its discharge to...
You are tasked with conducting BOD studies for a waste treatment facility and its discharge to a nearby river. You are told that the facility removes 93% of the BOD in total with a discharge rate of 1.0 m3 /s. you sample the receiving water and find that it has a 0.5 mg/L deficit from saturation concentration (saturation is at 9.7 mg/L) and a BOD5 content of 10 mg/L. The river flows at a speed of 0.25 m/s and has...
You are tasked with conducting BOD studies for a waste treatment facility and its discharge to...
You are tasked with conducting BOD studies for a waste treatment facility and its discharge to a nearby river. You are told that the facility removes 93% of the BOD in total with a discharge rate of 1.0 m3 /s. you sample the receiving water and find that it has a 0.5 mg/L deficit from saturation concentration (saturation is at 9.7 mg/L) and a BOD5 content of 10 mg/L. The river flows at a speed of 0.25 m/s and has...
8. A wastewater has a dissolved oxygen concentration of 2.0 mg/L and a discharge rate of...
8. A wastewater has a dissolved oxygen concentration of 2.0 mg/L and a discharge rate of 1.1 m3/s. The river into which it is being discharged has DO equal to 8.3 mg/L, a flow rate of 1.4 m3/s and a temperature of 200C. Assuming complete and instantaneous mixing, estimate the initial dissolved oxygen deficit of the mixture of wastewater and river water just downstream from the discharge point. The saturated valued of DO at 200C is 9.1 mg/L.
A waste stream has a dissolved oxygen concentration of 1.5 mg/L, a flow of 0.5 m3...
A waste stream has a dissolved oxygen concentration of 1.5 mg/L, a flow of 0.5 m3 /s, a temperature of 26°C, and an ultimate BOD (or BODu) of 48 mg/L. The waste stream is discharged into a river that is running at 2.2 m3 /s at a saturated DO, a temperature of 12°C, and an ultimate BOD of 1.6 mg/L. A) Calculate the mixing (a) temperature and (b) ultimate BOD for the river water immediately after discharge of the waste...