Question

An ion with a charge of 3 is accelerated into the 1.79 m flight tube of...

An ion with a charge of 3 is accelerated into the 1.79 m flight tube of a linear time-of-flight (TOF) mass spectrometer with an acceleration voltage of 15.0 kV. It takes the ion 76.5 μs to reach the detector. What is the m/z of the ion? The first attempt was 5.47 x 10^-5 was incorrect

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
An ion is accelerated into the 1.33 m flight tube of a linear time-of-flight (TOF) mass...
An ion is accelerated into the 1.33 m flight tube of a linear time-of-flight (TOF) mass spectrometer with an acceleration voltage of 25.0 kV. It takes the ion 81.1 microseconds to reach the detector. What is the m/z of the ion? ( Dont forget to convert units!)
An accelerating voltage of 7.00 kV is used to accelerate ions into the mass analyzer tube...
An accelerating voltage of 7.00 kV is used to accelerate ions into the mass analyzer tube of a magnetic sector mass spectrometer, which has a radius of curvature of 9.49 cm. If ions of m/z 531.8 reach the detector, what is the strength of the magnetic field that is applied perpendicular to the length of the mass analyzer tube?
For a time-of-flight (TOF) mass analyzer that is 1.0 m long a) what would be the...
For a time-of-flight (TOF) mass analyzer that is 1.0 m long a) what would be the flight time for an ion with a m/z ratio of 58 if the accelerating voltage used was 3000 V? b) what would be the flight time for an ion with a m/z ratio of 57 if the accelerating voltage used was 3000 V?
An ion of mass m and charge q is accelerated by a potential difference of V...
An ion of mass m and charge q is accelerated by a potential difference of V and allowed to enter a magnetic field B. In the field it moves in a semi-circle, striking photographic plate at a distance x from the slit. Show that the mass of the ion is given by ?=(?^2??^2) /8?.
A mass spectrometer is a device for separating particles of different masses from a mixture. For...
A mass spectrometer is a device for separating particles of different masses from a mixture. For example, the technology is used to investigate qualitative and quantitative changes within thousands of biologically active components such as proteins, lipids and metabolites. A mass spectrometer consists of three sections: The accelerator The velocity selector The magnetic chamber (1) Accelerator (acc): In the accelerator, there is only an uniform Electric field due to a potential difference Vacc across two vertical plates separated from a...
A mass spectrometer is a device for separating particles of different masses from a mixture. For...
A mass spectrometer is a device for separating particles of different masses from a mixture. For example, the technology is used to investigate qualitative and quantitative changes within thousands of biologically active components such as proteins, lipids and metabolites. A mass spectrometer consists of three sections: The accelerator The velocity selector The magnetic chamber (1) Accelerator (acc): In the accelerator, there is only an uniform Electric field due to a potential difference Vacc across two vertical plates separated from a...
ADVERTISEMENT
Need Online Homework Help?

Get Answers For Free
Most questions answered within 1 hours.

Ask a Question
ADVERTISEMENT