Question

An endothermic reaction is carried out in a coffee-cup calorimeter (with water). Which statement(s) is(are) incorrect...

An endothermic reaction is carried out in a coffee-cup calorimeter (with water). Which statement(s) is(are) incorrect for this process?

I. The temperature of the water decreases.

II. The enthalpy change for the reaction equals qH2O.

III. Heat is absorbed by the water.

IV. The enthalpy change for the reaction is positive.

V. The products have higher enthalpy than the reactants.

Homework Answers

Answer #1

I. The temperature of the water decreases. -- > TRUE since system absorbs energy

II. The enthalpy change for the reaction equals qH2O. --> false, since it must acocount the calorimeter aswell

III. Heat is absorbed by the water. --> true, endothermic by definition

IV. The enthalpy change for the reaction is positive. -> true, for rxn system, endothermic

V. The products have higher enthalpy than the reactants. --> false, heat is released, so products have less energy

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
When 7.56 g of NaCl is added to a coffee cup calorimeter, the water temperature changes...
When 7.56 g of NaCl is added to a coffee cup calorimeter, the water temperature changes by 4.1 ºC. If the heat of solution (the enthalpy change upon dissolving in water) is 3.8 kJ/mol, what mass of solution must be in the cup? Assume the specific heat capacity of the solution is the same as the specific heat capacity of water.
A coffee-cup calorimeter can be used to study the "cold pack reaction," the process that occurs...
A coffee-cup calorimeter can be used to study the "cold pack reaction," the process that occurs when solid ammonium nitrate dissolves in water. (dC= degrees celcius) NH4NO3(s) -----> NH4+(aq) + NO3-(aq) suppose 25.0 grams of solid ammonium nitrate at 23.0 dC is added to 250. mL of water at the same temperature. After all the solid is dissolved, the temperature is measured to be 15.6dC. Calculate the energy change, in kJ/mole, for this reaction, and state whether the reaction is...
A coffee cup calorimeter initially contains 125g of water at 24.2oC. 10.5g of potassium bromide also...
A coffee cup calorimeter initially contains 125g of water at 24.2oC. 10.5g of potassium bromide also at 24.2oC is added to the water. After the KBr dissolves the final temperature is 21.1oC. Calculate the enthalpy change for dissolving the salt in J/g and kJ/mol. Assume specific heat of solution is 4.18J/goC.
In the laboratory a "coffee cup" calorimeter, or constant pressure calorimeter, is frequently used to determine...
In the laboratory a "coffee cup" calorimeter, or constant pressure calorimeter, is frequently used to determine the specific heat capacity of a solid, or to measure the enthalpy of a solution phase reaction.   Since the cup itself can absorb energy, a separate experiment is needed to determine the heat capacity of the calorimeter. This is known as calibrating the calorimeter and the value determined is called the calorimeter constant.   One way to do this is to use a common metal...
An exothermic reaction liberates 7.58 kJ of heat in a coffee cup calorimeter containing 157 grams...
An exothermic reaction liberates 7.58 kJ of heat in a coffee cup calorimeter containing 157 grams of solution. The temperature of the solution in the calorimeter increases by 11.2°C. How much heat was absorbed by the calorimeter? Assume the specific heat of the solution is 4.184 J/g•°C. show work please a. 223J b. 7.36kj c. 657J d. 5820J e. -223J
In a coffee-cup calorimeter experiment, 10.00 g of a soluble ionic compound was added to the...
In a coffee-cup calorimeter experiment, 10.00 g of a soluble ionic compound was added to the calorimeter containing 75.0 g H2O initially at 23.2°C. The temperature of the water increased to 31.8°C. What was the change in enthalpy for the dissolution of the compound? Give your answer in units of joules per gram of compound. Assume that the specific heat of the solution is the same as that of pure water, 4.18 J ⁄ (g ⋅ °C).
In a coffee-cup calorimeter, 130.0 mL of 1.0 M NaOH and 130.0 mL of 1.0 M...
In a coffee-cup calorimeter, 130.0 mL of 1.0 M NaOH and 130.0 mL of 1.0 M HCl are mixed. Both solutions were originally at 26.8°C. After the reaction, the final temperature is 33.5°C. Assuming that all the solutions have a density of 1.0 g/cm and a specific heat capacity of 4.18 J/°C ⋅ g, calculate the enthalpy change for the neutralization of HCl by NaOH. Assume that no heat is lost to the surroundings or to the calorimeter. Enthalpy change...
A coffee-cup calorimeter contains 130.0 g of water at 25.3 ∘C . A 124.0-g block of...
A coffee-cup calorimeter contains 130.0 g of water at 25.3 ∘C . A 124.0-g block of copper metal is heated to 100.4 ∘C by putting it in a beaker of boiling water. The specific heat of Cu(s) is 0.385 J/g⋅K . The Cu is added to the calorimeter, and after a time the contents of the cup reach a constant temperature of 30.3 ∘C . Part A Determine the amount of heat, in J , lost by the copper block....
When 10.0 g KOH is dissolved in 100.0 g of water in a coffee-cup calorimeter, the...
When 10.0 g KOH is dissolved in 100.0 g of water in a coffee-cup calorimeter, the temperature rises from 25.18 ˚C to 47.53 ˚C. Calculate the ∆Hrxn for the dissolution process. Assume that the solution has a specific heat capacity of 4.184 J/gK
In a coffee-cup calorimeter, 50.0 mL of 0.100 M AgNO3 and 50.0 mL of 0.100 M...
In a coffee-cup calorimeter, 50.0 mL of 0.100 M AgNO3 and 50.0 mL of 0.100 M HCl are mixed. The two solutions were initially at 22.60°C, and the final temperature is 23.40°C. Assume that the specific heat and density of the solution after mixing is the same as that of water. a. Is this reaction exothermic or endothermic? b. Write a balanced reaction for this experiment. Make sure that you put in the states of each reactant and product. c....