Question

Determining the Calcium content of antacid tablets:: Would the following procedural errors cause the calculated calcium...

Determining the Calcium content of antacid tablets::

Would the following procedural errors cause the calculated calcium content to be too high, too low, or unaffected? Briefly explain

1) an insufficient amount of HCL was added to completely dissolve the sample.

2) the buret containing the standard calcium solution was not rinsed properly and contained some water at the time it was filled.

Homework Answers

Answer #1

1

2HCl +Ca2+ -> CaCl2 + H2

if insufficient HCl is added then the actual number of moles of calcium reacting will be lesser than actual and Calcium content calculated will be less than actual

2.

If Some water is already present in buret before adding solution , it can lead to minor deviations from actual value. Reason behind this is that water present if is hard water will contain reidual amount of calcium.

This will lead to a higher calculated calcium content than actual

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
Discussion. Explain whether each of the errors below would cause your calculated Ksp value to be...
Discussion. Explain whether each of the errors below would cause your calculated Ksp value to be higher or lower than the tabulated value. Assume you are using method 1 to calculate Ksp. It is also possible that the error would have no effect on the measured Ksp value (so it really wouldn’t be an error). (1 point each) 1. The calcium hydroxide solution was prepared at the last minute. Adequate time was not given for equilibrium to be reached between...
Would the following hypothetical errors cause a higher or lower percent yield? Explain your answer in...
Would the following hypothetical errors cause a higher or lower percent yield? Explain your answer in each case. A lab finding the amount of H2 gas produced along with the percent yield. A buret with a flask containing HCL and aluminum was used to cause the reaction. a. A student forgot to subtract the vapor pressure of water from the atmospheric pressure while doing the calculations. High Low b. A student held the leveling bulb way below the buret’s water...
Would the following procedural changes cause the experimentally determined mass percent NH3 in Ni(NH3)nCl2 to be...
Would the following procedural changes cause the experimentally determined mass percent NH3 in Ni(NH3)nCl2 to be too high, too low, or unchanged? Briefly explain each answer. a) Describe the color and apperance changes you observed when you dissolved NiSO4 * 6H2O in distilled water and then added NH3 solution. b) Descrie the color and apperance changes you observed when you dissolved Ni(NH3)nCl2 in distilled water and then added NH3 solution. c) Suggest an explanation for the changes you described in...
For each of the following determine whether the calculated molarity would be too low, too high,...
For each of the following determine whether the calculated molarity would be too low, too high, or unaffected and explain why? a. You added 1.0 zinc (instead of 0.3-0.4g) to your unknown. b. You added 50 ml DI (instead of 25mL) to your 10.00 mL unknown sample and then added the Zn c. the cooper was not completely dry before weighing
ADVERTISEMENT
Need Online Homework Help?

Get Answers For Free
Most questions answered within 1 hours.

Ask a Question
ADVERTISEMENT