Calculate the wavelength ranges to be scanned for CHCl3 and CCl4 for the (a) Stokes spectra and (b) anti-Stokes spectrum assuming that the wavelength of the laser is 532.2 nm and that the range of vibrational frequencies is 100-3200 cm^-1 for CHCl3 and 100-1000 cm^-1 for CCl4
wavenumber (cm-1 ) = 1/wavelength (nm)
wavelength of the laser = 532.2nm which corresponds to 532.2 x 10-7 cm
wavenumber = 1/ (532.2 x 10-7) = 1.87 x 104 cm-1
Peaks range for CHCl3 will be 100 -3200 cm^-1
stroke line = (1.87 x 104 ) - 100 = 1.86 x 104 = 535.05 nm.................................. for 100 cm-1
= (1.87 x 104) - 3200 = 1.53x 104 = 653.59 nm .................................. for 3200 cm-1
antisroke = (1.87 x 104 ) + 100 = 1.88x x 104 = 532nm.................................. for 100 cm-1
=(1.87 x 104) + 3200 = 2.19 x 104 = 457 nm .................................. for 3200 cm-1
For CCl4
stroke = (1.87 x 104) -1000 = 1.77 x 104 = 565 nm .................................. for 1000 cm-1
antistroke = (1.87 x 104) +1000 = 1.97 x 104 = 508 nm .................................. for 1000 cm-1