Question

For size-exclusion chromatography, how would one increase ​BOTH​ column resolution and accuracy of a molecular weight...

For size-exclusion chromatography, how would one increase ​BOTH​ column resolution and accuracy of a molecular weight calculation of a substance?

Homework Answers

Answer #1

These answers are fully based on the instrumental side, So to get good column resolution in size exclusion chromatography, there must be a 10% difference in molecular mass . Molecular weight can be improved based on flow rate, mobile phase and relation between concentration and sample volume.

Operate instrument at or near minimum of the van Deemter plot (HETP* vs. linear velocity),adjust peak width and area,avoid polymer-packing interactions during the mobile phase selection to get zero enthalpy change.

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
what are 2 ways to achieve a better resolution of two proteins on a size exclusion...
what are 2 ways to achieve a better resolution of two proteins on a size exclusion chromatography column? What are 2 reasons for protein recovery loss from a size exclusion chromatogrpahy column?
(Size exclusion chromatography) How do the colors of the fractions correspond to the postitions of the...
(Size exclusion chromatography) How do the colors of the fractions correspond to the postitions of the peaks?
explain how size exclusion chromatography can be used to change the buffer of a protein sample...
explain how size exclusion chromatography can be used to change the buffer of a protein sample (buffer exchange). How does this process work and what does the buffer of the sample end up changing?
Explain. Emulsion polymerization allows one to increase both the rate of polymerization and the molecular weight...
Explain. Emulsion polymerization allows one to increase both the rate of polymerization and the molecular weight of the polymer using a single parameter
1. Which of the following answers is (are) true about size exclusion chromatography? a. large proteins...
1. Which of the following answers is (are) true about size exclusion chromatography? a. large proteins elute first b. small proteins interact more with the column c. proteins larger than the cutoff size do not elute d. will be used to purify GFP 2. Which of the following is (are) not true about ion exchange chromotagraphy? a. positively charged proteins elute first b. negatively charged proteins elute first c. uncharged proteins elute first d. hydrophobic proteins elute first 3. The...
What effect would using a more polar mobile phase in column chromatography have? How would the...
What effect would using a more polar mobile phase in column chromatography have? How would the purity of acetylferrocene be affected by starting with a mobile phase of ethyl acetate instead of hexane?
How would you separate a mixture of benzhydrol, benzophenone, and biphenyl using column chromatography (i.e. which...
How would you separate a mixture of benzhydrol, benzophenone, and biphenyl using column chromatography (i.e. which is the best eluent or mixture of eluent, order of addition of the eluents, order of elution, ect.)?
Some characteristics of three proteins are listed in the table below: Protein Molecular Weight (Da) Isoelectric...
Some characteristics of three proteins are listed in the table below: Protein Molecular Weight (Da) Isoelectric point (pI) Does the Protein Contain a heme moiety? 1 65,000 5.5 No 2 54,000 10.0 No 3 14,500 4.5 Yes a.(2 points) What type of chromatography separates proteins based on size? b. (2 points) What type of chromatography separates proteins based on their charge? c.(10 points) Could gel filtration chromatography be used to separate a mixture containing Protein 2 and 3? Clearly explain...
Describe how (e.g., increase or decrease in accuracy), and explain why, selective predation on marked individuals...
Describe how (e.g., increase or decrease in accuracy), and explain why, selective predation on marked individuals would affect your population size estimate.
How hard would it be to make FTP use one channel (both command and data over...
How hard would it be to make FTP use one channel (both command and data over the same socket) instead of two?