Question

Which one would elute first from the column chromotographythat has a stationary phase and a weak...

Which one would elute first from the column chromotographythat has a stationary phase and a weak polar solvent? Explain your answer.

Hexane

Hexan-1-ol

Hexene

Hexan-1-one

Homework Answers

Answer #1

Polarity: Hexane < Hexene < Hexanone < Hexanol

If in column chormatography, a stationary phase is polar phase (without modified silica column) then most polar hexan-1-ol will elute last as it will interact strongly with stationary phase and least polar compound Hexane will elute first as it will interact weakly with stationary phase.

Now, if you use modified column and reversed the polarity of stationary phase from polar to non-polar then least polar compound, hexane will elute at last and most polar compound hexanol will elute first.

In case of normal column chromatography we use silica gel as a stationary phase and hence it is strongly polar stationary phase. Hence, hexane being least polar compound will interact less with stationary phase and elute first. Whereas, hexanol being most polar, will elute at last.

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
which is the more polar compound between Benzyl Alcohol and Methyl Benzoate? Which compound would elute...
which is the more polar compound between Benzyl Alcohol and Methyl Benzoate? Which compound would elute from a normal-phase column first and why?
Column Chromatography Lab: Explain what would happen if you first used the mixed solvent (CH2Cl2/EtOAc), instead...
Column Chromatography Lab: Explain what would happen if you first used the mixed solvent (CH2Cl2/EtOAc), instead of hexane to elute the column filled with the mix of ferrocene and acetylferrocene?1
mobile phase, length of column, solvent flow rate and stationary phase composition, which will be the...
mobile phase, length of column, solvent flow rate and stationary phase composition, which will be the easiest to change and give desired effect? why?
Answer the following about chromatography a. A normal phase column chromatography for the separation of a...
Answer the following about chromatography a. A normal phase column chromatography for the separation of a polar and a nonpolar compound calls for a sequential elution of the following two solvents: Methylene chloride & Hexanes Which solvent should be used first? Please explain b. A student loaded a mixture onto a small silica chromatography column in 1 mL of methanol, then proceeded to elute with hexanes/ethyl acetate/methanol gradient. The student found that all of the mixture came off in the...
Column Chromatography Theory and Background. I have started but would like to see an example of...
Column Chromatography Theory and Background. I have started but would like to see an example of what can else can be used. Some key points in my background need to include. Describe Column chromatography and its applications Choosing solvents for column chromatography sample and column size packing column two methods, adding sample, eluting column, and monitoring column Column chromatography is used to purify individual chemical compounds from mixtures. Generally, it is used in a glass tube from 5 mm to...
Which one of the following organic classes will elute off first in column and thin-layer chromatography?...
Which one of the following organic classes will elute off first in column and thin-layer chromatography? a. carboxylic acids b. esters c. hydrocarbons d. aromatic hydrocarbons
The stationary phase of the GC columns in the organic chemistry labs is silicone oil, and...
The stationary phase of the GC columns in the organic chemistry labs is silicone oil, and so the boiling points of the sample compounds determine the order of elution. The highest boiling species is the last to elute from the column. In the analysis of your distillation fractions by GC, the peak that elutes firstfrom the column will correspond to which component of the mixture?
1. Which of the following solvents is considered the most polar? Which of the following solvents...
1. Which of the following solvents is considered the most polar? Which of the following solvents is considered least polar? Hexane Acetone 70% hexane–30% acetone 2. Which of the following compounds is considered the most polar? Chlorophyll-a Chlorophyll-b Carotene 3. When using column chromatography to separate the pigments in spinach, which solvent from Question 1 do you start with? Which solvent do you use next? 4. In no more than TWO sentences, explain why it is necessary to change the...
2) The following two solvent systems were found to separate compounds X and Y by flash...
2) The following two solvent systems were found to separate compounds X and Y by flash chromatography: • The solvent that placed X in the optimal Rf range is 10:1 hexane: ethyl acetate • The solvent that placed Y in the optimal Rf range is 10:4 hexane: ethyl acetate Which is the more polar compound, X or Y? 3) In order to separate a mixture of X and Y as in problem (2) by flash chromatography, you decide to do...
1. Which of the following solvents is considered the most polar? Which of the following solvents...
1. Which of the following solvents is considered the most polar? Which of the following solvents is considered least polar? a.) Hexane b.) Acetone c.) 70% hexane–30% acetone 2. Which of the following compounds is considered the most polar? a.) Chlorophyll-a b.) Chlorophyll-b c.) Carotene 3. When using column chromatography to separate the pigments in spinach, which solvent from Question 1 do you start with? Which solvent do you use next? 4. In no more than TWO sentences, explain why...