Question

An activated sludge process is being used to treat wastewater from a small town of 50,000...

An activated sludge process is being used to treat wastewater from a small town of 50,000 people, which includes intermittent industrial discharges that may have a toxic impact on the performance of the wastewater treatment plant(WWTP) a) What type of online equipment would you recommended be installed for early warnings of wastewater treatment failutre? b) Which parameters would you recommend be measured and where would these be positioned in the WWTP?

Homework Answers

Answer #1

A) Online analyzers have advantages over traditional equipments, they requires less supervision and visits and can give more reliable informations. Online-analyzers are available in markets for early failure of treatment plants. AM200 On-Line Ammonia Analyzer, CT200 On-Lline UV COD Analyzer, NT200 On-Line Nitrate Analyzer, FL200 On-Line Fluorometer, CR200 On-Line Chromium VI Analyzer etc.

B) Three components are very important in waste water treatment plant. These are nitrate level, dissolved oxygen and ammonia in wastewater and these parameters are related to each other. It is very important to monitor their level and adjust while plant is running. Failure in this can result in high level of contamination into streams receiving wastewater. Along with this monitoring of total and reactive phosphorus, alkalinity and pH should also be considered.  

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
An activated sludge process is being used to treat wastewater from a small town of 50,000...
An activated sludge process is being used to treat wastewater from a small town of 50,000 people, which includes intermittent industrial discharges that may have a toxic impact on the performance of the wastewater treatment plant(WWTP) a) What type of online equipment would you recommended be installed for early warnings of wastewater treatment failutre? b) Which parameters would you recommend be measured and where would these be positioned in the WWTP?
A completely mixed activated sludge process is designed to treat 20,000 m3 /d of domestic wastewater...
A completely mixed activated sludge process is designed to treat 20,000 m3 /d of domestic wastewater having a BOD5 concentration of 250 mg/L following primary treatment. The NPDES permit requirement for effluent BOD5 and TSS is 20 mg/L for each. The biokinetic parameters have been established as: yield = 0.6 , k = 5/d, Ks = 60 mg/L, and kd = 0.06/d. The MLVSS concentration in the aeration tank is to be maintained at 3000 mg/L and the ratio of...
You have been retained to design a wastewater treatment plant using a conventional activated sludge process...
You have been retained to design a wastewater treatment plant using a conventional activated sludge process for a town of 40,000 people. The industrial flow contribution to the sewer system is 300,000 gallons per day. Effluent discharge standards require effluent BOD5 and total suspended solids concentration of <10 mg/l. Assume the following design criteria are applicable: Domestic sewage flow = 100 gal/cap/day (including I/I) BOD loading = 0.18 lbs/cap/day TSS loading = 0.20 lbs/cap/day BOD removal in primary = 33%...