The 400 mm x 500 mm column is reinforced with 8 – 25 mm ∅ ????...

The 400 mm x 500 mm column is reinforced with 8 – 25 mm ∅ ???? ????????????? ?????? ?? ???ℎ ?????. ?he 400 mm side is perpendicular to the x – axis, d’= 65, fc’ = 27.6 MPa, and fy = 414 MPa. Determine the safe load Pu that the column could carry at an eccentricity of
(a) 150 mm along the x − axis and 75 mm along the y − axis from the geometric centroid of the column. (b) 300 mm from the y – axis

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
Design a wall footing to support a 300 mm reinforced concrete wall with dead load of...
Design a wall footing to support a 300 mm reinforced concrete wall with dead load of 292KN/m and live load of 200 KN/m. The bottom of the footing is 1.20 m below the final grade, the soil weighs 15,700 N/m3. The allowable soil pressure is 190 Kpa. fy = 276.5 Mpa, fc’ = 27.6 Mpa.
A reinforced concrete column, 5.0 m high has a cross section of 400 mm x 400...
A reinforced concrete column, 5.0 m high has a cross section of 400 mm x 400 mm. it is reinforced by four steel bars each 20 mm in diameter and carries a load of 1000 kN. Young’s modulus for steel is 200,000 N/mm2 and for concrete is 15,000 N/mm2. Determine the deformation in mm? please show solution
A rectangular beam having b=300 mm and d=575 mm, spans 5.5 m face to face of...
A rectangular beam having b=300 mm and d=575 mm, spans 5.5 m face to face of simple supports. It is reinforced for flexure with 4φ32 bars that continue uninterrupted to the ends of the span. It is to carry a service dead load wD=30 kN/m (including self-weight) and a service live load =45 kN/m both uniformly distributed along the span. Design the shear reinforcement using φ10 vertical U stirrups. Use the equation (a) for Vc. Material strengths are fc’=22 and...
2. (a) A braced column which is 300 mm square is restrained such that it has...
2. (a) A braced column which is 300 mm square is restrained such that it has an effective height of 4.5 m. Classify the column as short or slender. (b) The column supports: (1) an ultimate axial load of 500 kN and a bending moment of 200 kNm, or (2) an ultimate axial load of 800 kN and bending moments of 75 kNm about the x-axis and 50 kNm about the y-axis. Design the longitudinal steel for both load cases...